(MPIO multipathing software, etc.) in the conguration. Congure targets using portals
on each controller.
Create fault-tolerant logical storage units—Create LUNs using fault-tolerant RAID levels and
striping methods.
When assigning system names and aliases, use only the following characters:
Uppercase alpha characters (A-Z)
Lowercase alpha characters (a-z)
•Numericcharacters(0-9)
Special characters (! # = ( ) ; , . and space)
When accessing the SMU, expand the browser to full screen or a minimum size of 1024 x 768
pixels. Other settings may distort the display or cause items to not display.
When planning and conguring logical drives:
Optimize performance and redundancy by striping the drives in the array across separate
storage enclosures on different SCSI buses, especially in mirrored environments using
RAID 1+0.
Set the drive rebuild priority to high to minimize exposure during a drive failure.
Customize the RAID level and striping method to the type of data that will be stored on the
logical drive.
NOTE:
Depending on the number of physical hard drives included in a storage unit, the SMU may suggest
RAID 6 (ADG) as the default RAID level, which offers a high level of fault tolerance and usable disk
capacity, but at a signicant cost to I/O performance. For comparable fault tolerance but higher
performance, consider using RAID 1+0 when fault tolerance is desired and performance is more
important than usable capacity. Reserve RAID 6 (ADG) for situations when fault tolerance is desired,
but usable capacity is more important than performance.
After conguring the storage, remember to:
Verify that each initiator has been granted access to the target.
Control access to the storage through the use of VLANs, CHAP authentication, and ACLs.
Draw physical and logical diagrams of your network:
Hardware/device diagram—Physical layout of the entire network, including device names
and cabling.
Storage diagram—Hard drive and storage system conguration, including RAID levels.
Path/Accessibility diagram—Access information, including which devices are allowed to
communicate with each other.