Hp StorageWorks 1510i Modular Smart Array Manual do Utilizador Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 99
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 66
Setting the pref
erredpathforaLUN(PreferredPath)
NOTE:
This task is available for dual-controller congurations only.
To manually (explicitly) set controller ownership of a LUN:
1. Select an already-congured logical drive from the system component list, and then select the
Preferred Path task.
2. Expand the Preferred Path drop-down box and select a controller.
IMPORTANT:
If the Redundancy Setting mode is set to Automatic”, path ownership may automatically switch
from one controller to the other, depending on the processing load, as the system attempts
to balance the processing load between the two controllers. To permanently set the path for
a LUN, the Redundancy Setting mode must be set to ’Manual”. For more information, see
Disabling auto-path switching (Redundancy Settings)”onpage64.
Viewin
g detailed component information (More Information)
To view
detailed information about a system component, select the desired component, and then select
More Information. The following image illustrates sample information displayed for a target.
HP Storage Management Utility user guide
67
Vista de página 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 98 99

Comentários a estes Manuais

Sem comentários