Hp StorageWorks 1510i Modular Smart Array Manual do Utilizador Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 99
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 32
Fundamental ta
sks, in initial conguration sequence
Conguring a ne
w system includes the following tasks, performed in the following sequence:
•Conguring management and data ports
•Conguring hard drives
•Creatingstor
age targets
Adding authorized initiators
Conguring management and data ports
As described in the installation documents, the array connects to the network switch from its Ethernet
iSCSI module.
IMPORTANT:
In dual-controller congurations, an additional Ethernet iSCSI module is installed in the chassis, providing
the redundant path to a separate iSCSI network switch. Ports on both modules must be congured.
When conguring management and data ports, consider the following:
Isolate management trafcfromstoragetrafc, by assigning IP addresses in different LAN
segments.
Assign one (or more) IP addresses to each port, and then assign one (or more) TCP portals
to each IP address.
Enable/disable the following management services as needed for your environment:
TELNET (default: disabled)
•SSH(default:enabled)
HTTP (default: enabled)
•HTTPS(default:enabled)
SNMP (default: enabled)
Assign IP addresses and TCP portals to the data ports as outlined on your Path/Accessibility
Diagram. (When conguring the storage targets, each target is assigned to a specicgroupofIP
portals, controlling access to the storage and the ow of storage trafc.)
NOTE:
The maximum supported number of IP addresses and portals may differ, depending on the storage system
and the model of its supported array controller. See your system user documents for more information.
Conguring the management port
IMPORTANT:
Dual-controller congurations should congure the management port associated with each controller.
The default management port for controller A is MA0.
The default management port for controller B is MB0.
1. To clarify the display, expand the View as drop-down box and select the iSCSI view.
2. Expand (+) the component list for an installed MSA1510i controller.
HP Storage Management Utility user guide
33