16 Powering on the extended library
Power on both Libraries. The Libraries can be powered on in either order.
The initialization sequence is faster when the lower Library is powered
on first.
NOTE:
The Library Extender receives power from the Libraries; it does
not have its own power cord or power button.
Check the LEDs
Green when the master Library is
powered on and the Extender is
installed correctly.
1. Library Extender power status
Green when the Extender is oper-
ating correctly. Flashing when the
Extender has failed with a hard
error and is no longer functional.
2. Master Library connection and
Library Extender status
Green when the lower library is
powered on and the Extender is
installed correctly.
3. Lower Library connection status
All three LEDs will be green when the Extender is installed correctly and
functional. Check the LEDs on the Extender to verify that the Extender is
operating correctly.
Magazines and mailslots
Magazine and mailslot numbering begins with the lower Library and
continues with the master (upper) Library.
Storage slot numbering
Slot numbers (without mailslots
enabled)
Extended Library Configuration
Master LibraryLower LibraryMaster LibraryLower Library
25–721–24MSL4048MSL2024
49–961–48MSL4048MSL4048
25–1201–24MSL8096MSL2024
49–1441–48MSL8096MSL4048
Mailslot numbering
The mailslots in both Libraries can be configured for use in the extended
library.
Mailslot numbers (with all
mailslots enabled)
Extended Library Configuration
Master LibraryLower LibraryMaster LibraryLower Library
M2–M4M1MSL4048MSL2024
M4–M6M1–M3MSL4048MSL4048
M2–M16M1MSL8096MSL2024
M4–M19M1–M3MSL8096MSL4048
Tape drives
Tape drives are numbered starting with the lower Library and continuing
with the master Library.
Any tape drive in the extended Library can host the SCSI Library
interface. The default is the lowest tape drive in the lower Library.
Power supply redundancy
Both Libraries must have a working power supply for the extended library
to operate. To have total power supply redundancy, both Libraries must
have working redundant power supplies. In an extended library, if only
one Library has redundant power supplies installed, the extended library
will continue to operate in case of a power supply failure in that Library.
An extended library containing an MSL2024 cannot have total power
supply redundancy because the MSL2024 only has one power supply.