HP Modular Smart Array 500 Starter Kit Guia do Utilizador Página 111

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 186
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 110
HP StorageWorks 2300 Modular Smart Array CLI reference guide 111
show auto-write-through-trigger
show awt
See show auto-write-through-trigger.
Description Shows the system's write-through trigger settings. When a trigger condition occurs and the trigger is
enabled, the RAID controller cache mode changes from write-back to write-through. Alias: show
awt.
Syntax
show auto-write-through-trigger
Example Show the system's auto-write-through trigger settings:
# show auto-write-through-trigger
Auto Write-Through Triggers
---------------------------
Controller Failure: Disabled
SuperCap Failure: Enabled
CompactFlash Failure: Enabled
Power Supply Failure: Disabled
Fan Failure: Disabled
Temperature Exceeded: Disabled
Partner Notify: Disabled
Auto Write Back: Enabled
See also set auto-write-through-trigger
Vista de página 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 185 186

Comentários a estes Manuais

Sem comentários