HP StorageWorks 2300 Modular Smart Array CLI reference guide 143
show ports
Description Shows information about host and expansion ports on both controllers. Alias of show channels.
Syntax
show ports
Output Port
Controller ID and port number
Media
FC(P): Fibre Channel Point-to-Point
FC(L): Fibre Channel-Arbitrated Loop
FC(-): Not applicable, as when the port is disconnected
SAS: Serial Attached SCSI
Target ID
Enclosure WWN or serial number
Status
Whether the port is operational, has a problem, or is disconnected
Speed (A)
Actual host-port link speed, or blank if not applicable.
Speed (C)
FC only. Configured host-port link speed:
FC: 2Gb or 4Gb (Gbit/sec)
Blank if not applicable
Topo (C)
FC only. Configured topology
PID
FC only. Primary ID, or blank if not applicable
SID
FC only. Secondary ID, or blank if not applicable
Example Show port information for a system with a single FC controller:
# show ports
Port Media Target ID Status Speed(A) Speed(C) Topo(C) PID SID
----------------------------------------------------------------------------
A1 FC(L) 207000C0FF000015 OK 2Gb 2Gb Loop 0
A2 FC(L) 217000C0FF000015 OK 2Gb 2Gb Loop 1
A3 FC(L) 207000C0FF000015 OK 2Gb Auto Loop 0
A4 FC(L) 207000C0FF000015 OK 2Gb Auto Loop 0
----------------------------------------------------------------------------
See also set host-parameters