HP StorageWorks 2300 Modular Smart Array CLI reference guide 145
show redundancy-mode
Description Shows the redundancy status of the system.
Syntax
show redundancy-mode
Output Redundancy Mode
The redundancy mode, also called the operation mode.
Active-Active ULP: Both controllers are active using ULP (Unified LUN Provisioning), which
means 128 LUNs are available for mapping volumes.
Active-Active: FC only. Both controllers are active, and each has 128 LUNs for mapping
volumes owned by that controller only.
Independent Cache Performance Mode: Cache mirroring and failover between
controllers is disabled, which results in improved write performance but at a risk of loss of
unwritten data if a controller failure occurs while there is data in the controller's cache memory.
Single-Controller: There is only a single controller in the enclosure.
Redundancy Status
Redundant: Both controllers are operational.
Operational but not redundant: In active-active mode, one controller is operational and
the other is offline. In single-controller mode, the controller is operational.
Redundant with independent cache: Both controllers are operational with cache
mirroring disabled.
Controller ID Status
Operational: The controller is operational.
Down: The controller is installed but not operational.
Not Installed: The controller is not installed.
Controller ID Serial Number
Controller module serial number
Not Available: The controller is down or not installed.
Example Show the redundancy status of a dual-controller FC system with one controller offline:
# show redundancy-mode
System Redundancy
-----------------
Redundancy Mode: Active-Active
Redundancy Status: Operational but not redundant
Controller A Status: Down
Controller A Serial Number: Not Available
Controller B Status: Operational
Controller B Serial Number: 00C0FF0A4326
Show the redundancy status of an operational single-controller system:
# show redundancy-mode
System Redundancy
-----------------
Redundancy Mode: Single Controller
Redundancy Status: Operational but not redundant
Controller A Status: Operational
Controller A Serial Number: 00C0FF0A4318
Controller B Status: Not Installed
Controller B Serial Number: Not Available