HP StorageWorks 2300 Modular Smart Array CLI reference guide 77
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
smart enabled|disabled|on|off
Optional. Enables or disables Self-Monitoring Analysis and Reporting Technology in disk drives.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when cache backup
power is not fully charged or fails.
sync-cache-mode immediate|flush
Optional. Sets the option that controls how the SCSI SYNCHRONIZE CACHE command is handled.
• immediate: Good status is returned immediately and cache content is unchanged. This option
is the default.
• flush: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system forces a controller shutdown if a temperature is detected that
exceeds system threshold limits.
utility-priority low|medium|high
Optional. Sets the priority at which jobs (such as vdisk verification and reconstruction but not
background scrub) run with respect to I/O operations competing for the system's processors: low,
medium, or high.
Example Enable partner firmware upgrade:
# set advanced-settings partner-firmware-upgrade enabled
Info: Command completed successfully. - Parameter 'partner-firmware-upgrade' was
set to 'enabled'.
Success: Command completed successfully. - The settings were changed
successfully.
See also • show advanced-settings