Enabling bidirectional CHAP during discovery session and single-direction CHAP
during normal session
Table 17 (page 104) lists the settings you use to enable bidirectional CHAP during a discovery
session and single-direction CHAP during a normal session.
Table 17 CHAP bidirectional settings
Microsoft initiator secret settingsMPX200 secret settings
Setting (example)ActionSetting (example)Source
hpstorageworksGeneral Tab SecrethpstorageworksiSCSI Port
CHAPsecret0Add Target PortalCHAPsecret01Discovered iSCSI
Initiator
CHAPsecret01Log on to TargetN/AiSCSI Presented
Target
NOTE: These are examples of secret settings. Configure CHAP using settings that apply to your network environment.
1. Enable CHAP for the MPX200 discovered iSCSI initiator entry (CHAP can be enabled via CLI
only).
a. If the iSCSI initiator is not listed when you execute the set chap command, do one of
the following:
From HP P6000 Command View, select Hosts, and then select the Add Host tab.
Enter the IQN name string.
From the CLI, enter the initiator add command and add the iSCSI initiator that
performs the discovery.
b. If the iSCSI initiator is listed under the set chap command, then enable CHAP secret
(for example: CHAPsecret01).
Select the index of the iSCSI initiator.
To Enable CHAP, select 0, and then enter the CHAP secret.
2. Enable CHAP for the MPX200 iSCSI port:
a. To enable CHAP for the MPX200 iSCSI port using HP Command View:
Select the appropriate iSCSI Controller, then select the IP Ports tab, and then select
the appropriate IP Port.
Under Security, select Enabled in CHAP Status, and then enter the CHAP Secret (for
example, hpstorageworks).
Select the Save Changes tab to save the changes.
b. To enable CHAP for the MPX200 iSCSI port using the MPX200 CLI:
Enter the set chap command.
Select the appropriate Portal iqn name index that the initiator logs in to.
Select 0 to enable CHAP.
Enter a CHAP secret. For example: hpstorageworks.
104 MPX200 iSCSI configuration rules and guidelines