Chapter 3: Programming Commands118
Set paper low threshold extension
ASCII US EXT US n
Hexadecimal 1F 03 1F n
Decimal 31 03 31 n
Value of n: 0 = Zero
1 = 5 feet
2 = 10 feet
3 = 15 feet
4 = 20 feet
5 = -5 feet
6 = -10 feet
Default: 0 (Zero)
Setstheamountoffootagefortheextensionin5footincrementsbetween0and20feet.
Enable or disable USM canned status
ASCII US EXT 0x28 n
Hexadecimal 1F 03 28 n
Decimal 31 03 40 n
Value of n: 0 = Disable
1 = Enable
Default: 0 (Disable)
EnablesordisablestheUSMcannedstatusfeature.
Send diagnostic pages to comm port
ASCII US EXT 0x2C n
Hexadecimal 1F 03 2C n
Decimal 31 03 44 n
Value of n: 0 = Disabled
1 = Enabled
Sendsthediagnosticpagestothecommportifenabled.
Enable or disable EJ action via operator control
ASCII US EXT 0x2E n
Hexadecimal 1F 03 2E n
Decimal 31 03 46 n
Value of n: 0 = Disable
1 = Enable
Enablesordisablestheneedforoperatorcontrolforelectronicjournaling.