Chapter 3: Programming Commands 31
Perform partial knife cut
ASCII SUB ESC m
Hexadecimal 1A 1B 6D
Decimal 26 27 109
Partiallycutsthereceipt.Thedefaultsettingleaves5mm(0.20inch)ofpaperontheleftedge.(Seesettingpartialcut
distance in diagnostics.)
Therearetwocodes(Hex1Aor1B6D)forthiscommandandbothcodesperformthesamefunction.
Formulas
Thecutedgeis144dotrowsor18mm(0.71inch)abovetheprintstation.
Exceptions
Thecommandisvalidonlyatthebeginningofaline.ASCIISUB,(0x1A),isignoredinLEGACYemulation.Linefeedis
executedrst,ifthebufferisnotempty.
Generate tone
ASCII ESC BEL
Hexadecimal 1B 07
Decimal 27 7
Generatesanaudibletone.Performedbytheprintertosignalcertainconditions.
Related information
ThiscommandisignoredinLEGACYemulation.
Select peripheral device (for multi-drop)
ASCII ESC = n
Hexadecimal 1B 3D n
Decimal 27 61 n
Value of n: 0 (bit 0), device not selected
1 (bit 0), device selected
Default: 1 (bit 0), device selected
Selectsthedevicetowhichthehostcomputersendsdata.
Related information
Otherbitsofn(1–7)areundenedandignored.
Whentheprinterisdisabledbythiscommand,itignorestransmitteddatauntiltheprinterisre-enabledbythe
same command.