HP NonStop Shadowbase Command Definitions
Queue Manager Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
287
Initial Changed
Version Version Values Default Value Specifications Alter
2.000 None Valid MAT full filename No
Partial file name up to the AA prefix
1 to reset
To know if your version of HP Shadowbase can use the parameter, the
first column titled ‘Initial Version’, is for when the parameter was first
introduced. The next column is for if and when the parameter was last
changed. If the parameter has a last changed version then the values in
the columns following, are as of that version. The next column provides
the default value. Next is provided, either the minimum to maximum
values, or the listed value specifications. The value in the last column,
titled ‘Alter’, is set to ‘Yes’ for those parameters that can be altered while
running. If the value under ‘Alter’ is ‘No’ then these parameters cannot be
altered once the Queue Manager is started.
The syntax is:
SET [ QMGR ] qmgr_parameter [ , qmgr_parameter ] ...
qmgr_parameter is one of the following:
ABNORMALSHUTDOWN {DRAINSTOP}
{DRAINPAUSE}
{STOP}
Initial Changed
Version Version Values Default Value Specifications Alter
4.092 DRAINSTOP Valid Action No
This parameter is used to control the behavior of the QMGR and its
attached Consumer in the event of AUDMON failure. When set to
DRAINSTOP, the QMGR and attached CONS drains as much of the
queue as possible and then shutdown. Any transactions still in progress
at the end of the queue are aborted. In the case of DRAINPAUSE, the
QMGR and CONS continue draining the queue and then pause until a
DRAIN command (described below) is received. In order to configure
ABNORMALSHUTDOWN to DRAINPAUSE, a TIDFILE must be
configured for the attached CONS. When set to STOP, the QMGR and its
attached CONS immediately shutdown upon detecting a failure of
AUDMON. The default value is DRAINSTOP.
BACKUPCPU num