362 HSG80 Users Guide
The partition number appears in the first column, followed by the size
and starting block of each partition.
5. Present each partition to the host by giving it a unit number the host can
recognize. (You can skip this step until you are ready to put the
partitions online.) Optionally, you can append Unit switch values. If you
do not specify switch values, the default values are applied.
Use the following command to present partitions to the host:
ADD UNIT unit-number storageset-name PARTITION=partition-number
switch
6. Verify the unit numbers for the partitions using the following command:
SHOW storageset-name
Example
The following example shows the commands you would use to create
Raid1, a three-member RAIDset, then partition it into four storage
units:
ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000
INITIALIZE RAID1
CREATE_PARTITION RAID1 SIZE=25
CREATE_PARTITION RAID1 SIZE=25
CREATE_PARTITION RAID1 SIZE=25
CREATE_PARTITION RAID1 SIZE=LARGEST
SHOW RAID1
Partition number Size Starting Block Used by
1 1915 (0.98 MB) 0 Raid1
2 1915 (0.98 MB) 1920 Raid1
3 1915 (0.98 MB) 3840 Raid1
4 2371 (1.21 MB) 5760 Raid1
.
.
.