Hp Array Controller HSG V8.7 Software Manual do Utilizador Página 175

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 174
Troubleshooting 421
SET PROMPT
SET NOPROMPT
enable and disable the display of the CLI prompt string following
the log identifier %EVL, or %LFL, or %FLL. This command
is useful if the CLI prompt string is used to identify the controllers in
a dual-redundant configuration (see Appendix B, CLI Commands,
for instructions to set the CLI command string for a controller). If
enabled, the CLI prompt will be able to identify which controller
sent the log to the local terminal. By default, the prompt is set (SET
PROMPT).
SET TIMESTAMP
SET NOTIMESTAMP
enable and disable the display of the current date and time in the first
line of an event or last-failure log. By default, the timestamp is set
(SET TIMESTAMP)
SET FMU_REPAIR_ACTION
SET FMU_NOREPAIR_ACTION
enable and disable the inclusion of repair actions with SHOW
LAST_FAILURE and SHOW MEMORY_SYSTEM_FAILURE
commands. By default, the repair actions are not shown (SET FMU
NOREPAIR_ACTION). If repair actions are enabled, the command
outputs display all of the recommended repair actions associated
with the instance or last-failure codes used to describe an event.
SET FMU VERBOSE
SET FMU NOVERBOSE
enable and disable the inclusion of instance and last failure code
descriptive text with SHOW LAST_FAILURE and SHOW
MEMORY_SYSTEM_ FAILURE commands. By default, this
descriptive text is not displayed (SET FMU_NOVERBOSE). If the
descriptive text is enabled, it identifies the fields and their numeric
content that comprise an event or last-failure entry.
SET CLI_EVENT_REPORTING
SET NOCLI_EVENT_REPORTING
enable and disable the asynchronous errors reported at the CLI
prompt (for example, swap signals disabled or shelf has a bad
power supply). Preceded by %CER. By default, these errors are
reported (SET CLI_EVENT_REPORTING). These errors are
cleared with the CLEAR ERRORS_CLI command.
Table 43 FMU SET Commands (Continued)
Command Result
Vista de página 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 575 576