Replacement Procedures 519
6. Enter Y(es) and press return. FRUTIL displays the following:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
.
.
.
Insert the controller module, without its program card, in
slot A [or B] within x minutes, xx seconds.
Note A countdown timer allows a total of two minutes to install the
controller. If you exceed two minutes, this controller will exit
FRUTIL and resume operations.
Caution ESD can easily damage a controller. Wear a snug-fitting,
grounded ESD wrist strap.
Make sure you align the controller in the appropriate guide rails. If you
do not align the controller correctly, damage to the backplane can
occur.
7. Ensure that the program card is not in the new controller and insert the
new controller into its slot. Engage its retaining levers.
FRUTIL will display the following:
The configuration has two controllers.
To restart the other controller:
1. Type restart other_controller.
2. Press and hold the reset button while inserting the
program card on the slot A [or B] controller, then release
the reset button.
The controller will restart.
Field Replacement Utility terminated.