Event Reporting: Templates and Codes D9
Backup Battery Failure Event Sense Data Response
The HSG80 controller Value Added Services software component
reports backup battery failure conditions for the various hardware
components that use a battery to maintain state during power failures
via the Backup Battery Failure Event Sense Data Response (see Figure
D6).
Instance Codes (byte offset 32-35) are described in Table D1,
Instance Codes on page D18.
ASC and ASCQ codes (byte offsets 12 and 13) are described in
Table D7, ASC and ASCQ Codes on page D85.
Figure D6 Template 12 - Backup Battery Failure Event Sense
Data Response Format
For more information on Instance Codes, see page D16.
For a table of ASC and ASCQ codes, see page D85.
off bit 7 6 5 4 3 2 1
Unusd
Unused
Unused
Unused
Unused
Unused
Unused
Error Code
0
1
2
3-6
7
8-11
12
13
14
1517
1831
32-35
36
37
3853
5469
7073
74-75
76
77103
104107
108159
0
Sense Key
Additional Sense Length
Additional Sense Code (ASC)
Additional Sense Code Qualifier (ASCQ)
Reserved
Reserved
Reserved
Reserved
Instance Code
Template
Template Flags
Controller Board Serial Number
Controller Software Revision Level
Memory Address
Reserved
LUN Status