Hp Array Controller HSG V8.7 Software Manual do Utilizador Página 143

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 142
Creating Storagesets 365
Enabling Autospare
With AUTOSPARE enabled on the failedset, any new disk drive that is
inserted into the PTL location of a failed disk drive is automatically
initialized and placed into the spareset. If initialization fails, the disk
drive remains in the failedset until you manually delete it from the
failedset.
To enable autospare use the following command:
SET FAILEDSET AUTOSPARE
To disable autospare use the following command:
SET FAILEDSET NOAUTOSPARE
During initialization, AUTOSPARE checks to see if the new disk drive
contains metadatathe information that indicates it belongs to, or has
been used by, a known storageset. If the disk drive contains metadata,
initialization stops. (A new disk drive will not contain metadata but a
repaired or re-used disk drive might. To erase metadata from a disk
drive, add it to the controllers list of devices, then set it to be
TRANSPORTABLE and initialize it.)
Deleting a Storageset
If the storageset you are deleting is partitioned, you must delete each
partitioned unit before you can delete the storageset. Use the following
steps to delete a storageset:
1. Show the configuration using the following command:
SHOW STORAGESETS
2. Delete the unit number shown in the Used by column. Use the
following command:
DELETE unit-number
3. Delete the name shown in the Name column. Use the following
command:
DELETE storageset-name
4. Verify the configuration using the following command:
SHOW STORAGESETS