C4 HSG80 Users Guide
■●●●❍❍❍
38 Controller operation terminated
Last Failure event required
termination of controller operation
(e.g. SHUT DOWN VIA CLI)
Reset controller
■●●❍●●●
37 Software-induced controller reset
expected
Software-induced reset failed
Replace controller
■●●❍●●❍
36 Hardware-induced controller reset
expected
Automatic hardware reset failed
Replace controller
■●●❍●❍●
35 An unexpected bugcheck occurred
during Last Failure processing
Last Failure Processing interrupted
by another Last Failure event
Reset controller
■●●❍❍●●
33 NVPM structure revision too low
NVPM structure revision number
is less than the one that can be
handled by the software version
attempting to be executed
Verify that the program card contains
the latest software version. If the error
persists, replace controller.
■●●❍❍●❍
32 Code load program card write
failure
Attempt to update program card
failed
Replace card
■●●❍❍❍●
31 ILF$INIT unable to allocate
memory
Attempt to allocate memory by
ILF$INIT failed
Replace controller
Table C1 Solid OCP Patterns (Continued)
Pattern
OCP
Code
Error Repair Action