Hp XP7 Storage Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Armazenamento Hp XP7 Storage. HP XP7 Storage User Manual [fr] [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Abstract

HP XP7 RAID Manager User GuideAbstractThis document describes and provides instructions for using the RAID Manager software to configure and perform o

Página 2 - DescriptionDateEdition

Table 1 Available RAID Manager functions on each storage system (continued)Storage systemsFunctionXP7P9500XP24000/XP20000Disk ArrayXP12000 DiskArrayXP

Página 3 - Contents

4 Starting up RAID ManagerYou can begin using the RAID Manager software after you have installed the RAID Managersoftware, set the command device, cre

Página 4 - 4 Contents

5. Set the log directory (HORCC_LOG) in the command execution environment as needed.6. If you want to perform Continuous Access Synchronous operations

Página 5 - Contents 5

6. If you want to perform Continuous Access Synchronous operations, do not set the HORCC_MRCFenvironment variable. If you want to perform Business Cop

Página 6 - 6 Contents

1. Create the configuration definition files.For a new installation, use the configuration definition sample file that is supplied(SYS$POSIX_ROOT:[HOR

Página 7 - Contents 7

C:\HORCM\tool\>svcexe• Usage for adding [HORCM_START_SVC]: svcexe /A=command_path◦ for deleting [HORCM_START_SVC]: svcexe /D◦ for specifying a serv

Página 8 - 8 Contents

When you update the RAID Manager software, the sample script file(\HORCM\Tool\HORCM0_run.txt) is updated. Therefore, if you directly update the sample

Página 9 - 1 Overview

5 Provisioning operations with RAID ManagerThis chapter describes storage provisioning operations with RAID Manager.About provisioning operationsProvi

Página 10 - Provisioning function

system using the raidcom reset command_status command. You can check the information in SSB1and SSB2 by using the raidcom get error_message command.In

Página 11 - Precheck function

Table 27 Asynchronous commands of the configuration setting command (continued)Command syntaxFunctionraidcom add rcu_path -cu_free <serial#> <

Página 12

Corresponding commandDescriptionOperation typeraidcom unlock resource -resource_name <resource group name>Unlock resource.raidcom get resourceDi

Página 13 - User authentication

Command execution modesRAID Manager provides two command execution modes: transaction mode that executes byspecifying a script file with -zt option, a

Página 14 - 14 Overview

Corresponding commandDescriptionOperation typeraidcom get pool [-key <keyword>]Display pool information for ThinProvisioning, Thin Provisioningf

Página 15 - Data protection

Corresponding commandDescriptionOperation type-device_grp_name <device group name> [<devicename>]}[-user_threshold <threshold_1> [&l

Página 16 - Command device

Corresponding commandDescriptionOperation typeraidcom disconnect path -path_grp <path group#> -port <port>-external_wwn <wwn strings>

Página 17 - Command device guarding

Corresponding commandDescriptionOperation type(see themanuals forraidcom delete rcu_path -cu_free <serial#> <id> <pid> -mcu_port<

Página 18 - AI = 14 TI = 0 CI = 1

Operation methodSpecify the name of device group (max: 32 characters) and the device name in the device group(max: 32 characters), and execute a comma

Página 19

GROUP = grp1 , DEVICE = data1 , UnitID = 0 , LDEV = 17003(0x426B)[1] , PORT= CL8-A , LUN = none :raidcom: LUN 3(0x3) will be used for adding.doneC:\H

Página 20 - Command flow

Resource group operationsCreating resource groupsTo create resource groups, perform the following provisioning operations.CommandDescriptionOperationS

Página 21 - HORCM operational environment

CommandDescriptionOperationStepwant to delete. At that time, allocationof resources to the resource group:meta_resource must be finished.raidcom add r

Página 22

Internal volume operationsCreating internal volumes (open-systems)To create LDEVs of internal open-systems volumes and make the LDEVs available to the

Página 23

Figure 30 Script examples of virtual volume operation (Thin Provisioning) (1/3)Internal volume operations 119

Página 24

Table 2 Summary of the checking functions (continued)ExecutionConfig checkContext checkSyntax checkCommand syntaxNot executedNot executedExecutedExecu

Página 25 - Configuration definition file

Figure 31 Script examples of virtual volume operation (Thin Provisioning) (2/3)Figure 32 Script examples of virtual volume operation (Thin Provisionin

Página 26

Creating internal volumes (Mainframe volume)To create LDEVs of internal volumes (Mainframe volume) and make the LDEVs available to the host,perform th

Página 27 - HORCM_MON

Figure 33 Script examples of internal volume (Mainframe volume) operationScript examplesThe following shows script examples for internal open-system v

Página 28

Figure 34 Script examples of internal open-system volume operation (1/2)Internal volume operations 123

Página 29 - \\.\CMD-30095-250-CL1-A

Figure 35 Script examples of internal open-system volume operation (2/2)Virtual volume (Thin Provisioning) operationsCreating virtual volumes (Thin Pr

Página 30

Executed commandDescriptionOperation overviewStep<size>} [-emulation <emulationtype>][-location <lba>] [-mp_blade_id<mp#>]raid

Página 31

Virtual volume (Thin Provisioning for Mainframe) operationsCreating virtual volumes (Thin Provisioning for Mainframe)To create LDEVs of virtual volume

Página 32

Figure 36 Script examples of virtual volume operation (Thin Provisioning for Mainframe) (1/2)Figure 37 Script examples of virtual volume operation (Th

Página 33

Note *1: The multiple tiering pool is disabled when a pool is creating at RAID Manager. Andmultiple media cannot be registered as a pool volume when a

Página 34

Creating virtual volumes (Smart Tiers)Use the following operations to create LDEVs of virtual volumes (Smart Tiers) and making the LDEVsavailable to t

Página 35

Figure 1 Overview of out-of-band and in-band operationsThe following table provides a comparison of in-band and out-of-band operations.Table 3 Compari

Página 36

Executed commandDescriptionOperation overviewStepraidcom add ldev -pool {<pool ID#> |<pool naming> | snap} -ldev_id <ldev#>Specify p

Página 37 - Business Copy

Figure 39 Script examples of virtual volume operation (Smart Tiers) (2/3)Virtual volume (Smart Tiers) operations 131

Página 38

Figure 40 Script examples of virtual volume operation (Smart Tiers) (3/3)External volume operationsCreating external volumesUse the following provisio

Página 39

Executed commandDescriptionOperation overviewStep< y|n > | -cache_inflow < y|n > |-mp_blade_id <mp#>}raidcom get external_grp [-exte

Página 40

Figure 41 Script Examples of External Volume Operation (1/3)Figure 42 Script Examples of External Volume Operation (2/3)134 Provisioning operations wi

Página 41 - RAID Manager software files

Figure 43 Script Examples of External Volume Operation (3/3)Cache Partition operationsCache Partition operations using RAID Manager include migrating

Página 42

Displaying CLPR informationThe raidcom get clpr command lists and displays the status of the CLPRs in the storage system. Ifno CLPRs have been created

Página 43

For details about the RAID Manager commands for Performance Control operations, see the HPXP7 RAID Manager Reference Guide.You can give a nickname (PF

Página 44

Controlling server performanceThe server performance is controlled by setting the priority of the I/O operation, the upper limit,and a threshold (per

Página 45 - RAID Manager log files

# raidcom get hba_wwn -port CL4-E-0PORT GID GROUP_NAME HWWN Serial# NICK_NAMECL4-E 0 Linux_x86 210000e08b0256f8 63528 ORA_NODE0_CT

Página 46

LDEV grouping functionIn RAID Manager before supporting P9500, it was required to define a copy group for theconfiguration definition file on each hos

Página 47 - Command logging for audit

# raidcom add pfc_wwn -port CL4-E -pfc_nameORA_NODE0_CTL_0 -hba_wwn 210000e0,8b0256f8Set the PFC name (ORA_NODE1_CTL_1) for the WWN (210000e08b039c15)

Página 48

If you delete WWN from the PFC targets by using the PFC group name, the PFC setting and thegroup under the specified port are deleted. If the same PFC

Página 49 - Logging raidcom command

Executed commandDescriptionOperation overviewStepraidcom map resource -ldev_id <ldev#>-virtual_ldev_id <ldev#> [- ssid<ssid>-emulati

Página 50 - /var/log/raidcom.err

6 Data replication operations with RAID ManagerThis chapter describes data replication operations with RAID Manager.About data replication operationsT

Página 51

Figure 44 Concept of paired volumesAddressing paired logical volumes: The correspondence of paired logical volumes to their physicalvolumes is defined

Página 52 - User environment variable

Continuous Access Synchronous provides remote mirroring functionality, linkage functionality withfailover switching, and remote backup operations amon

Página 53

mirror volumes of the P-VOL are expressed as virtual volumes using the mirror descriptors (MU#0-2)in the configuration diagram as shown below.Figure 4

Página 54 - Security setting

Figure 47 Business Copy cascade volume pairsRestrictions for Business Copy cascading volumesPair Creation. Pair creation of SVOL (oradb1) can only be

Página 55

S/PVOL are in a COPY, PAIR or PSUS state, the pairresync -restore command is rejected withEX_CMDRJE or EX_CMDIOE.Restriction for Continuous Access Syn

Página 56 - Controlling User Role

Figure 48 Server failover system configurationLegend• CM (Cluster Manager) : Demon process that keeps the consistency of the cluster by monitoringthe

Página 57 - Controlling user resources

provides failover operation commands that support mutual hot standby in conjunction withindustry-standard failover products (for example, MC/ServiceGu

Página 58 - Target resources

The swap option of the takeover command allows swapping of the primary and secondary volumedesignations, so if the primary and secondary volume are sw

Página 59

Unconformable: A pair of volumes are not conformable to each other as a pair (i.e. one pvol, onesvol). The takeover command execution terminates abnor

Página 60

a Synchronous state between the P-VOL and S-VOL. The Swap operation is required to copyNon-transmitted pvol data within a given timeout value (specifi

Página 61

volume to be used. The SVOL-takeover operation is required to copy Non-transmitted pvoldata within a given timeout value (specified by the -t <time

Página 62

PVOL-SMPL-takeover. PVOL-takeover can be specified per paired logical volume or per volumegroup.Continuous Access Asynchronous/Continuous Access Journ

Página 63 - Resource lock function

Legend• HORCM : The manager is a demon process, executes multiple commands, charges to a storagesystem through itself. Among the managers are connecte

Página 64

The MU number indicates that the pair is a Business Copy pair and not a Continuous AccessSynchronous pair. Once the correspondence between the paired

Página 65 - Context check

Table 30 Continuous Access Synchronous and Business Copy pair status (continued)SecondaryPrimaryBusiness Copy Pair StatusContinuous Access Synchronous

Página 66 - [-clpr <clpr#>]

Table 31 Continuous Access Journal pair status (continued)SecondaryPrimaryContinuous Access Journal Pair StatusStatusR/W enabledR enabledAfter Takeove

Página 67

Table 33 Pair status versus Business Copy commands (continued)Business Copy command-pairresyncpairsplitpaircreateResync-S option-C option-E option-spl

Página 68

2 RAID Manager software environmentThis chapter describes the RAID Manager software environment.Overview of the RAID Manager software environmentThe R

Página 69

If PVOL has non-reflected data in PAIR state:Behavior of first pairsplit at T0Behavior of OLD pairsplit at T0PVOL_PAIR from/to SVOL_PAIR(WD)T0 PVOL_PA

Página 70 - Configuration check

NOTE:• pairsplit ("simplex -S") of Snapshot volume is returned without verification of state transitionthat waits until SMPL state. In SMPL

Página 71

Table 35 Assignment of consistency group IDs (CTGIDs)AssignmentCTGIDCTG 0-127Continuous Access Asynchronous0 -127Continuous Access SynchronousCTG 0-12

Página 72 - LDEV grouping function

Figure 53 Sidefile quantity limitSidefile area: Sidefile area = 30% to 70% of cache as set on Remote Web Console (default sidefile= 50% for XP24000/XP

Página 73 - LDEV grouping function 73

Table 36 State table for Continuous Access Synchronous vs. Continuous Access AsynchronousTransferdata viaESCONWriting control on Cnt Ac-Sasync volumeD

Página 74

Figure 54 Continuous Access Asynchronous suspension conditionContinuous Access Synchronous/Continuous Access Asynchronous and ContinuousAccess Journal

Página 75 - Define device group

Table 37 Relationship between Continuous Access Synchronous pair statuses and fence levels (continued)Fence level and write responseContinuous Access

Página 76 - 4. Device group deletion

Because most UNIX file systems (excluding JFS and VxFS) have no journal files, the fence levelshould be defined as Never. When a takeover by the S-VOL

Página 77 - LDEV addition to device group

Creating a Snapshot pairThe RAID Manager command for creating a Fast Snap or Snapshot pair is the same as for BusinessCopy. However, Fast Snap pair ca

Página 78

Table 38 Snapshot Pairing Status (continued)SecondaryPrimaryPairing StatusP-VOLStatusR/W enabledR/W enabledThe differences of the updated data of the

Página 79 - Device group deletion

command devices (see “Alternate command device function” (page 18)) must be set to avoid dataloss and storage system downtime.Each command device must

Página 80 - Copy group function

Specifications for Auto LUNRAID Manager must be mapped to the port for pooling of RAID in order to control the volume ofthe external connection. There

Página 81 - When deleting a copy group

(5) HORCM instanceIt is possible to describe the original and target volume for the volume migration to MU# as anothergroup in horcm*.conf for HORCM i

Página 82 - LDEV addition to a copy group

It is possible to confirm the status for Auto LUN by using "-fe" option of the pairdisplay command.pairdisplay -g <group> -fe-feThis o

Página 83 - LDEV deletion from copy group

sdw CL2-G 63528 2769 - s/s/ss 000B E:16384 OPEN-V• R:Group: This displays the physical position of an LDEV according to mapp

Página 84 - Copy group deletion

Table 40 (page 174) shows the relations between the migration volume statuses and commandacceptances.Table 40 Command issues and pairing status transi

Página 85 - LDEV grouping function 85

Restrictions for Auto LUNAuto LUN must be used within the following restrictions:• Business Copy (HOMRCF). The operation for the volume migration must

Página 86

on the open system if RAID Manager is capable of delivering the timestamps and committing theJournal data with a CTQ-Marker.Thus, RAID Manager support

Página 87 - LDEV grouping function 87

HORCM CTQM#groupinterval (10ms)mode(optionaloradb300where• group is to be allowed as a group across multiple storage systems.• interval is the interva

Página 88

# pairdisplay -g ora -v jnltJID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# DOW PBW APW001 1 0 PJNN 1 0 00000c76 20 1

Página 89

(3) pairsplit -S option• Issues Freeze to CT group on each MCU• Issues Delete & Run to make a deleting state for CT group on each MCU• Searches/co

Página 90 - Journal Z (continued)

Figure 2 Current assignment sequenceFigure 3 Improved assignment sequenceThe command device performs the assignment of an instance through TWO phases

Página 91

• Repeats above until detecting an EOM(End Of Marker) marked on all RCU via RCU• Issues End of Delete to terminate a deleting stateNotice on system op

Página 92

To terminate this status, re-execute the RAID Manager command, then terminate suspending/deletingstatus after "JNL Consistency Restore".(8)

Página 93

(1) Cnt Ac-J 2x2182 Data replication operations with RAID Manager

Página 94 - HORCM_VCMD

(2) Cnt Ac-J 2x1Remote volume discoveryIn the configuration separating "Storage admin server (RAID Manager server)" and each productionserve

Página 95

Figure 58 Volume discoveryDiscovering a remote volumeThe inqraid command exports the device information discovered on the production servers. Thedevic

Página 96

# ls /dev/rdsk/c1t* | inqraid -CLI -export | ssh <RAID Managerhost> raidscan -find verifyDEVICE_FILE Group PairVol PORT TAR

Página 97

7 Data protection operations with RAID ManagerThis chapter describes data protection operations using RAID Manager.Data protection operationsUser data

Página 98

Restrictions on Data Retention volumes• File systems using Data RetentionWhen setting Data Ret to the UNIX file system volumes, the volumes must be mo

Página 99

Restrictions on Database Validator• Oracle® tablespace locationFile system-based Oracle files are not supported by Database Validator. All Oracledatab

Página 100 - 4 Starting up RAID Manager

◦Shows the fibre port, target ID, LDEV, and validation checking parameters for the specifiedvolumes based on the raidscan command.◦ Shows the journal

Página 101 - Two instances

to the LVM can use the alternate path PV-LINK. To avoid command device failure, RAID Managersupports an alternate command device function.• Definition

Página 102

Figure 59 Definition of the protection volumesData Protection Facility specificationsOnly the permitted volumes can be registered in horcm.conf. When

Página 103

OFF. Protection mode is enabled for the host that has Data Retention and ON commanddevice.Examples for configuration and protected volumesCase (1): Tw

Página 104 - ◦ for starting [HORCM0]:

The operation authority with CMD security enabledIf the CMD security is enabled, you have the operation authority for the LU which meets both ofthe fo

Página 105

# ioscan -fun | grep rdsk | raidscan -find instDEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV/dev/rdsk/c0t3d0 o

Página 106 - About provisioning operations

If either the local or the remote host (instance) has not been shown the Device_File, then pairoperations are rejected (except the local option such a

Página 107 - Asynchronous commands

# DB1 For MU# 1hd20-23Verifying a group for DB1. The following is an example of how to verify whether a DB volumegroup is mapped to a group (MU#1 for

Página 108 - LDEV nickname function

Table 44 Relation between HORCMPROMOD and command deviceModeHORCMPROMODCommand DeviceProtection modeDon't careProtection modeNon-protection modeN

Página 109

8 Examples of using RAID Manager commandsThis chapter provides examples of typical tasks performed using RAID Manager commands.Group version control f

Página 110

Figure 63 LDM volume configurationVolume discovery functionRAID Manager supports the volume discovery function on three levels showing the relationshi

Página 111

E:\Vol44\Dsk0 CL2-K 61456 194 - s/s/ss 0004 1:01-10 OPEN-3F:\Vol45\Dsk0 CL2-K 61456 194 - s/s/ss 0004 1:01-10 OPEN-3G:\Dmt1\Dsk1

Página 112

© Copyright 2014 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Página 113

Recognition of the control command area (LBA#). The host issues control commands through theraw I/O special file of a special LDEV. Since the specific

Página 114 - Operation method

mountvolCreates, deletes, or lists a volume mount point...MOUNTVOL [drive:]path VolumeNameMOUNTVOL [drive:]path /DMOUNTVOL [drive:]path /L \\?\Volu

Página 115

The following example flushes the system buffer associated with all groups for the local instance.raidscan -pi $Volume -find sync[SYNC] : ORA ORA_000[

Página 116 - Resource group operations

The raidscan-find sync command flushes the system buffer through finding a logical drivecorresponding to a group of the configuration file, without us

Página 117 - Execution example

Figure 65 Configurations with MSCS and Business Copy (HOMRCF)MSCS on Node2 will misunderstand the S-VOL as MSCS cluster resource, because the signatur

Página 118 - Internal volume operations

Harddisk0 CL2-K 61456 194 - s/S/ss 0004 1:01-10 OPEN-3Harddisk1 CL2-K 61456 256 - s/S/ss 0005 1:01-11 OPEN-35. After sta

Página 119

GPT disk for WindowsWindows supports the basic disk called GPT disk using GUID partition instead of the Signature.The GPT disk also can be used as an

Página 120

• -gplbaex option (Windows 2008/2012 Only)This option is used for displaying usable LBA on a Physical drive in units of 512 bytes, andis used to speci

Página 121 - Script examples

Mount and Sync used Volume{GUID} for Windows: RAID Manager supports the mount commandoption specified in the device object name, such as \Device\Hardd

Página 122

The addition of arguments for the host group to the raidscan command and the configurationfile means that it is not compatible with conventional CLI.

Página 123

# ls /dev/rdsk/c57* | raidscan -findg conf 0 -g ORAHORCM_DEV#dev_group dev_name port# TargetID LU# MU## /dev/rdsk/c57t4d1

Página 124

Figure 7 Command flowIssuing commands for LDEVs within a LUSE deviceA LUSE device is a group of LDEVs regarded as a single logical unit. Because it is

Página 125

1. Setting SLPR on the command device: The command device has an SLPR number and anassociated bitmap so you can set multiple SLPRs. You accomplish thi

Página 126

SLPR of the command device. In this case, -p CL3-A must be operated via RMINST1, as shown inthe following example.Figure 69 Operation across SLPRs usi

Página 127 - Operational flow

Figure 71 SLPR configuration on dual hostsTo operate SLPR#N, assign the command device. If HostB has a command device for SLPR#N, thepaircreate comman

Página 128

Figure 73 Operating SLPR#N by sharing the command deviceContinuous Access Synchronous using dual hostsIn the following example, the pair-operation com

Página 129

9 TroubleshootingThis chapter provides troubleshooting information for RAID Manager.General troubleshootingIf you have a problem with the RAID Manager

Página 130

Operational notes and restrictions for RAID Manager operationsFor maintenance of volumes used by RAID Manager and the HP features it supports, if a vo

Página 131

Notes and restrictionsItemsThe HORC Manager must not be an object of the process monitoring by the HA software(cluster manager), because HORCM should

Página 132 - External volume operations

Notes and restrictionsItemsIssue the Continuous Access Synchronous commands manually to the identified failed pairedvolume to try to recover it. If th

Página 133 - Script Examples

Table 45 System log messages (continued)Recommended actionCauseConditionMessage IDRestart the system, and contact the HPTechnical Support.An internal

Página 134

Table 46 Command error messagesValueRecommended actionConditionErrorError codemessage255Verify that HORCM is running byusing UNIX commands [ps - ef |g

Página 135 - Cache Partition operations

Figure 9 HORCM operational environmentRAID Manager instance configurationsThe basic unit of the RAID Manager software structure is the RAID Manager in

Página 136 - Displaying CLPR information

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code244Refer to the error message, anddesignate an approp

Página 137

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code# paircreate -g G1 -fnever -vl -nocopypaircreate: [EX

Página 138

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code230Please confirm the command name.An unknown command

Página 139

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code216Please confirm the serial # of thevolumes by using

Página 140

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code205Specify the appropriate object.Check the status of

Página 141

Table 46 Command error messages (continued)ValueRecommended actionConditionErrormessageError code131Check if the specified file exist ornot, and speci

Página 142

Table 47 Generic error codes (horctakeover and pair commands) (continued)ReturnValueError messageError codeCategory239No such groupEX_ENOGRPConfigurat

Página 143 - Features of paired volumes

Table 48 Generic error codes (raidscan, raidqry, raidar, horcctl)ValueError messageError codeCategory254Required Arg listEX_REQARGSyntax for Argument(

Página 144 - Synchronous

Table 49 Specific error codesValueError messageError codeCategory236Unmatched volume status within the groupEX_ENQVOLVolume Status(Unrecoverable)229In

Página 145 - Business Copy operations

The following describes the SSB codes that are returned by the replication commands and theconfiguration setting command (raidcom).SSB codes returned

Página 146 - Business Copy cascading pairs

Figure 10 RAID Manager instance configuration & componentsThe four possible RAID Manager instance configurations are:• One host connected to one s

Página 147 - Business Copy operations 147

Table 50 SSB codes returned by the configuration setting command (common)commonDescriptionError codeExecuting/AsyncError messageSSB2SSB1Unavailable to

Página 148

Table 51 SSB codes returned by raidcom add external_grp (continued)raidcom add external_grpDescriptionError codeExecuting/AsyncError messageSSB2SSB1Th

Página 149

Table 52 SSB codes returned by raidcom check_ext_storage external_grp (continued)raidcom check_ext_storage external_grpDescriptionError codeExecuting/

Página 150 - The Takeover-switch function

Table 53 SSB codes returned by raidcom delete external_grp (continued)raidcom delete external_grpDescriptionError codeExecuting/AsyncError messageSSB2

Página 151 - Swap-takeover function

Table 54 SSB codes returned by raidcom check_ext_storage path (continued)raidcom check_ext_storage pathDescriptionError codeExecuting/AsyncError messa

Página 152 - SVOL-takeover function

Table 55 SSB codes that are returned by raidcom disconnect external_grp command (continued)raidcom disconnect external_grpDescriptionError codeExecuti

Página 153 - PVOL-takeover function

Table 56 SSB codes that are returned by raidcom modify external_grp command (continued)raidcom modify external_grpDescriptionError codeExecuting/Async

Página 154

Table 57 SSB codes that are returned by raidcom modify port -loop_id command (continued)raidcom modify port -loop_idDescriptionError codeExecuting/Asy

Página 155 - Journal operations

Table 59 SSB codes that are returned by raidcom modify port -security _switch command (continued)raidcom modify port -security _switchDescriptionError

Página 156

Table 60 SSB codes that are returned by raidcom add ldev command (continued)raidcom add ldevDescriptionError codeExecuting/AsyncError messageSSB2SSB1T

Página 157

device that communicates with both RAID Manager instances (one on each host) and theprimary and secondary volumes of both RAID Manager instances• Two

Página 158

Table 60 SSB codes that are returned by raidcom add ldev command (continued)raidcom add ldevDescriptionError codeExecuting/AsyncError messageSSB2SSB1T

Página 159 - # pairdisplay -g oradb -fc

Table 60 SSB codes that are returned by raidcom add ldev command (continued)raidcom add ldevDescriptionError codeExecuting/AsyncError messageSSB2SSB1T

Página 160

Table 61 SSB codes that are returned by raidcom delete journal command (continued)raidcom delete journalDescriptionError codeExecuting/AsyncError mess

Página 161 - Access Journal volumes

Table 62 SSB codes that are returned by raidcom add journal command (continued)raidcom add journalDescriptionError codeExecuting/AsyncError messageSSB

Página 162

Table 62 SSB codes that are returned by raidcom add journal command (continued)raidcom add journalDescriptionError codeExecuting/AsyncError messageSSB

Página 163

Table 62 SSB codes that are returned by raidcom add journal command (continued)raidcom add journalDescriptionError codeExecuting/AsyncError messageSSB

Página 164

Table 63 SSB codes that are returned by raidcom modify journal command (continued)raidcom modify journalDescriptionError codeExecuting/AsyncError mess

Página 165

Table 66 SSB codes that are returned by raidcom add device_grp commandraidcom add device_grpDescriptionError codeExecuting/AsyncError messageSSB2SSB1I

Página 166 - Setting the fence level

Table 68 SSB codes that are returned by raidcom initialize ldev command (continued)raidcom initialize ldevDescriptionError codeExecuting/AsyncError me

Página 167 - Snapshot operations

Table 68 SSB codes that are returned by raidcom initialize ldev command (continued)raidcom initialize ldevDescriptionError codeExecuting/AsyncError me

Página 168 - Snapshot pair status

Table 4 Supported RAID Manager (HORCM) communicationMPE/iXHORCM 64 bitHORCM 32 bitHORCMbigbiglittlebiglittleAV-AVAVAVlittle32 bitAV-AVAVAVbigNA-AVAVAV

Página 169 - Controlling Auto LUN

Table 69 SSB codes that are returned by raidcom modify ldev -command_device (continued)raidcom modify ldev -command_deviceDescriptionError codeExecuti

Página 170 - Specifications for Auto LUN

Table 71 SSB codes that are returned by raidcom modify ldev -status nml command (continued)raidcom modify ldev -status nmlDescriptionError codeExecuti

Página 171 - Commands to control Auto LUN

Table 72 SSB codes that are returned by raidcom modify ldev -status blk command (continued)raidcom modify ldev -status blkDescriptionError codeExecuti

Página 172

Table 73 SSB codes that are returned by raidcom modify ldev -statusenable_reallocation/disable_reallocation/new_page_allocation/enable_relocation_poli

Página 173

Table 75 SSB codes that are returned by raidcom delete lun commandraidcom delete lunDescriptionError codeExecuting/AsyncError messageSSB2SSB1The other

Página 174

Table 76 SSB codes that are returned by raidcom add lun command (continued)raidcom add lunDescriptionError codeExecuting/AsyncError messageSSB2SSB1The

Página 175 - Overview

Table 76 SSB codes that are returned by raidcom add lun command (continued)raidcom add lunDescriptionError codeExecuting/AsyncError messageSSB2SSB1An

Página 176 - (3) Propagating Error suspend

Table 77 SSB codes that are returned by raidcom modify pool command (continued)raidcom modify poolDescriptionError codeExecuting/AsyncError messageSSB

Página 177 - Command specifications

Table 78 SSB codes that are returned by raidcom rename pool command (continued)raidcom rename poolDescriptionError codeExecuting/AsyncError messageSSB

Página 178

Table 79 SSB codes that are returned by raidcom delete pool command (continued)raidcom delete poolDescriptionError codeExecuting/AsyncError messageSSB

Página 179

HST1 horcm 1000 3000HORCM_CMD#unitID 0... (seq#30014)#dev_name dev_name dev_name/dev/rdsk/c0t0d0#unitID 1... (seq#30015)#dev_name dev_n

Página 180 - Notice on system operation

Table 80 SSB codes that are returned by raidcom add snap_pool command (continued)raidcom add snap_poolDescriptionError codeExecuting/AsyncError messag

Página 181 - Configuration examples

Table 80 SSB codes that are returned by raidcom add snap_pool command (continued)raidcom add snap_poolDescriptionError codeExecuting/AsyncError messag

Página 182 - (1) Cnt Ac-J 2x2

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1A pair can

Página 183 - Remote volume discovery

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1The comman

Página 184 - Discovering a remote volume

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1A Fast Sna

Página 185

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1A Fast Sna

Página 186 - Data protection operations

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1The specif

Página 187

Table 81 SSB codes returned by raidcom add snapshot (continued)raidcom add snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1A pair can

Página 188

Table 82 SSB codes returned by raidcom modify snapshot (continued)raidcom modify snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1The

Página 189 - Data Protection facility

Table 82 SSB codes returned by raidcom modify snapshot (continued)raidcom modify snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1A Sn

Página 190

Table 5 Configuration (HORCM_CONF) parameters (continued)LimitTypeDefaultParameterRecommended value = 8 char.or less31 charactersCharacter stringNoned

Página 191 - Data Protection facility 191

Table 82 SSB codes returned by raidcom modify snapshot (continued)raidcom modify snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1The

Página 192 - Permission command

Table 82 SSB codes returned by raidcom modify snapshot (continued)raidcom modify snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1The

Página 193 - New options for security

Table 84 SSB codes returned by raidcom delete snapshot (continued)raidcom delete snapshotDescriptionError codeExecuting/AsyncError messageSSB2SSB1betw

Página 194 - Permitting protected volumes

Table 85 SSB codes that are returned by raidcom add ssid commandraidcom add ssidDescriptionError codeExecuting/AsyncError messageSSB2SSB1The CU number

Página 195 - Environment variables

Table 86 SSB codes that are returned by raidcom delete ssid command (continued)raidcom delete ssidDescriptionError codeExecuting/AsyncError messageSSB

Página 196 - $HORCMPERM

Table 87 SSB codes that are returned by raidcom add thp_pool command (continued)raidcom add thp_poolDescriptionError codeExecuting/AsyncError messageS

Página 197

Table 87 SSB codes that are returned by raidcom add thp_pool command (continued)raidcom add thp_poolDescriptionError codeExecuting/AsyncError messageS

Página 198 - Volume discovery function

Table 88 SSB codes that are returned by raidcom modify rcu command (continued)raidcom modify rcuDescriptionError codeExecuting/AsyncError messageSSB2S

Página 199

Table 89 SSB codes that are returned by raidcom delete rcu_path command (continued)raidcom delete rcu_pathDescriptionError codeExecuting/AsyncError me

Página 200

Table 90 SSB codes that are returned by raidcom add rcu_path command (continued)raidcom add rcu_pathDescriptionError codeExecuting/AsyncError messageS

Página 201

(2) HORCM_CMDWhen using the in-band method, this command parameter (HORCM_CMD) defines the UNIXdevice path or Windows physical device number and speci

Página 202

Table 91 SSB codes that are returned by raidcom delete rcu command (continued)raidcom delete rcuDescriptionError codeExecuting/AsyncError messageSSB2S

Página 203

Table 92 SSB codes that are returned by raidcom add rcu command (continued)raidcom add rcuDescriptionError codeExecuting/AsyncError messageSSB2SSB1• C

Página 204

Table 93 SSB codes that are returned by raidcom delete ldev commandraidcom delete ldevDescriptionError codeExecuting/AsyncError messageSSB2SSB1It exce

Página 205 - GPT disk for Windows

Table 93 SSB codes that are returned by raidcom delete ldev command (continued)raidcom delete ldevDescriptionError codeExecuting/AsyncError messageSSB

Página 206

Table 94 SSB codes that are returned by raidcom delete hba_wwn commandraidcom delete hba_wwnDescriptionError codeExecuting/AsyncError messageSSB2SSB1T

Página 207 - Host group control

Table 97 SSB codes that are returned by raidcom reset hba_wwn command (continued)raidcom reset hba_wwnDescriptionError codeExecuting/AsyncError messag

Página 208

Table 100 SSB codes that are returned by raidcom modify port -port_speed command (continued)raidcom modify port -port_speedDescriptionError codeExecut

Página 209

Table 101 SSB codes that are returned by raidcom modify port -port_attribute command (continued)raidcom modify port -port_attributeDescriptionError co

Página 210 - SLPR configuration examples

Table 104 SSB codes that are returned by raidcom modify host_grp command (continued)raidcom modify host_grpDescriptionError codeExecuting/AsyncError m

Página 211 - Dual Hosts

Table 106 SSB codes that are returned by raidcom delete path commandraidcom delete pathDescriptionError codeExecuting/AsyncError messageSSB2SSB1The pa

Página 212

NOTE: To enable dual path of the command device under Solaris systems, make sure to includeall paths to the command device on a single line in the HOR

Página 213

Table 107 SSB codes that are returned by raidcom add path command (continued)raidcom add pathDescriptionError codeExecuting/AsyncError messageSSB2SSB1

Página 214 - 9 Troubleshooting

Table 109 SSB codes that are returned by raidcom monitor pool command (continued)raidcom monitor poolDescriptionError codeExecuting/AsyncError message

Página 215

Table 110 SSB codes that are returned by raidcom reallocate pool command (continued)raidcom reallocate poolDescriptionError codeExecuting/AsyncError m

Página 216

Table 113 SSB codes that are returned by raidcom add resource commandraidcom add resourceDescriptionError codeExecuting/AsyncError messageSSB2SSB1The

Página 217 - System log messages

Table 114 SSB codes that are returned by raidcom get resource commandraidcom get resourceDescriptionError codeExecuting/AsyncError messageSSB2SSB1An i

Página 218 - Command error messages

Table 116 SSB codes that are returned by raidcom modify clpr command (continued)raidcom modify clprDescriptionError codeExecuting/AsyncError messageSS

Página 219

Table 120 SSB codes that are returned by raidcom add pfc_wwn commandraidcom add pfc_wwnDescriptionError codeExecuting/AsyncError messageSSB2SSB1Perfor

Página 220

10 Support and other resourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/supportBefore con

Página 221

HP websitesFor additional information, see the following HP websites:• http://www.hp.com• http://www.hp.com/go/storage• http://www.hp.com/service_loca

Página 222

Table 123 Document conventions (continued)ElementConventionMonospace text• File and directory names• System output• Code• Commands, their arguments,

Página 223

Contents1 Overview...9About RAID Manager...

Página 224

To allow more flexibility, RAID Manager allows the following format.• For minimum specificationSpecifies to use any command device for Serial#30095 \\

Página 225

Glossaryallocation The ratio of allocated storage capacity versus total capacity as a percentage. Allocated storagerefers to those logical devices (LD

Página 226

to be associated with 1 to 36 LDEVs. Essentially, LUSE makes it possible for applications to accessa single large pool of storage.M-VOL Main volume.MC

Página 227 - Specific error codes

IndexAalternate command device, 18defining, 19asynchronous commandslist of provisioning, 107processing, 10, 106authorities for commands and operations

Página 228 - SSB codes

raidscan, raidqry, raidar, horcctl:troubleshooting, 226troubleshooting, 217, 227error messagestroubleshooting, 217examplesdirectory mound for Windows,

Página 229

cascading volumes, 147duplicated mirroring, 145in-system , 14local system configuration, 155operations, 143, 155pair status, 156paired volumes, 161rem

Página 230

HORCM_CMD#dev_name dev_name dev_name\\.\CMD-30095-250-CL1:/dev/rdsk/ \\.\CMD-30095-250-CL2• Basic Specificat

Página 231

For XP1024/XP128 Disk Array, RAID Manager supports four types of port names for host groups:• Specifying the port name without a host group: CL1-A CL1

Página 232

• MU#for Continuous Access Synchronous/Cnt Ac-J : Defines the mirror unit number (0 - 3) touse the redundant mirror for the identical LU on Continuous

Página 233

Figure 14 Configuration for multiple networks(5) HORCM_LDEVThe HORCM_LDEV parameter is used for specifying stable LDEV# and Serial# as the physicalvol

Página 234

The following values are defined.• Copy group: specifies a name of copy group. This is equivalent to the dev_group ofHORCM_DEV and HORCM_LDEV paramete

Página 235

Figure 15 Mirror descriptors and group assignmentConfiguration file and mirror descriptorsThe group name and MU# described in the HORCM_DEV parameter

Página 236

Table 6 Mirror descriptors and group assignments (continued)Cnt Ac-J onlyBC (Snapshot)onlyMU#0HORCM_DEV parameter in configuration fileMU#1-#3MU#1-#2(

Página 237

Figure 17 Pairdisplay on HORCMINST0Figure 18 Pairdisplay on HORCMINST1Figure 19 Pairdisplay on HORCMINST0Cascading connections for Continuous Access S

Página 238

Figure 20 Continuous Access Synchronous/Business Copy cascading connection and configurationfileFigure 21 (page 39) through Figure 24 (page 40) show C

Página 239

Logging raidcom command...49User-created files...

Página 240

Figure 22 Pairdisplay for Continuous Access Synchronous on HOST2 (HORCMINST)Figure 23 Pairdisplay for Business Copy on HOST2 (HORCMINST)Figure 24 Pair

Página 241

RAID Manager software filesThe RAID Manager software consists of files supplied with the software, log files created internally,and files created by t

Página 242

GroupUser*1ModeCommand nameFile nameTitlesysroot0544raidvchkdsp/usr/bin/raidvchkdspDB Validatorconfirmationsysroot0544raidvchkscan/usr/bin/raidvchksca

Página 243

Command nameFile nameTitlehorcmshutdown\HORCM\etc\horcmshutdown.exeHORCM shutdown scriptpairsyncwait\HORCM\etc\pairsyncwait.exeSynchronous waitinginqr

Página 244

RAID Manager files for OpenVMS-based systemsUserCommand nameFile nameTitlesyshorcmd$ROOT:[HORCM.etc]horcmgr.exeHORCMsys-$ROOT:[HORCM.etc]horcm.confHOR

Página 245

RAID Manager log and trace filesThe RAID Manager software (HORCM) maintains internal startup log files, execution log files, andtrace files that can b

Página 246

activation log, identify the error cause, and take the proper action. The system log file forUNIX-based systems is the syslog file. The system log fil

Página 247

RAID Manager trace filesThe command trace file is used for maintenance aiming at troubleshooting. It is not created normally.If a cause of an error ca

Página 248

For example setting 2MB size: HORCC_LOGSZ=2048 Export HORCC_LOGSZ• /HORCM/log*/horcc_HOST.conf fileThis file is used to describe HORCC_LOGSZ variable

Página 249

• Examples for execution/HORCM/log* directory[root@raidmanager log9]# ls ltotal 16drwxr-xr-x 3 root root 4096 Oct 27 17:33 curlog-rw-r--r-- 1 r

Página 250

Example of the configuration definition files when specifying a virtual storage machine bycommand options...

Página 251

The conditions to support the output of syslog fileThe conditions to support this function are explained in the following:Supported OSThis function is

Página 252

Table 10 Display information of the title rowOutput exampleItemJun 27 10:15:13 rmsolx86 raidcom: [ID 702911 user.info]Syslog fixed output part(Includi

Página 253

Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] User authentication has failed on Serial#(64568).Aug 24 12:24:27 raidmanager raidcom: PID:068

Página 254

3 RAID Manager functions on the P9500 and XP7 StorageThis chapter describes the RAID Manager functions for the P9500 and XP7 Storage systems.Command e

Página 255

NOTE: In Out-of-Band method, if you perform the microcode exchange of SVP, timeout of thecommand occurs. Execute the command again after finishing the

Página 256

command device can be restricted. For the details about the settings to HORCM_ALLOW_INST,please refer to "Configuration definition file".• S

Página 257

To enable the user authentication function, the user authentication mode of the command deviceaccessed by RAID Manager must be enabled.The user authen

Página 258

The target commandsRAID Manager checks execution authorities on the following commands that use command devices.• horctakeover, horctakeoff• paircreat

Página 259

Target resourcesThe following objects are arbitrarily defined as the resource groups by each user.• LDEV• Physical port• Host group• RAID group• Exter

Página 260

Table 15 Commands and operation authority managed by Remote Web Console and SVP (continued)Operation authority (Role)Executable commandAuthorityOperat

Página 261

Controlling server performance...138Checking WWN of host bus ad

Página 262

Table 15 Commands and operation authority managed by Remote Web Console and SVP (continued)Operation authority (Role)Executable commandAuthorityOperat

Página 263

Figure 27 Relation among user, command devices, and resource groupsTable 16 Relation between resource groups and command devicesCommandoperationsConfi

Página 264

Table 16 Relation between resource groups and command devices (continued)Commandoperationsusing theOut-of-BandmethodConfiguration changeReferenceOpera

Página 265

# raidcom get portThe execution results of CL1-A, CL3-A and CL5-A are displayed. The execution results of CL2-Aand CL4-A (the user does not have the a

Página 266

When executing the configuration setting command, the following checks can be done dependingon the above two mode types.• Syntax checkThis function ch

Página 267

Detailed description are provided in the following.CAUTION: Observe the following cautions:• For <script file>, specify an executable file name.

Página 268

<emulation type>][-location <lba>][-mp_blade_id <mp#>] [-clpr <clpr#>]Check with the attribute settingIt is checked wheth

Página 269

The command as the target of the check is shown below.• raidcom delete ldev {-ldev_id <ldev#> | -grp_opt <group option>-device_grp_name &l

Página 270

raidcom: LDEV(2) is already existing as status is [1] on UnitID# 0.raidcom_#6 : [EX_CTXCHK] Context Check errorC:\HORCM\etc>raidcom add ldev -parit

Página 271

CL1-B FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b01CL2-A FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b10CL2-B FIBRE TAR AUT EF N FCAL N 0 6453

Página 272

Overview...175Policy ...

Página 273

Check with deletion operationIt is checked to ensure that the operation is not intended to be performed for the host group thatis already deleted. If

Página 274

Check the operation for Host groupraidcom get host_grp -port <port> -store <work file>After acquiring the configuration information, execu

Página 275

Table 20 MP blade names and parameters for XP7 (continued)MP blade IDMP blade numberMP blade name1414MPB-2PL1515MPB-2PMLDEV grouping functionThe LDEV

Página 276

RAID Manager can be used to create a group of multiple LDEVs by defining device groups. Thisis accomplished by defining device groups in either the pr

Página 277

Device group definition methodsTo define a device group or copy group in the RAID Manager that supports P9500 or later, useone or both of following me

Página 278

Table 21 Reading of command device setting and group information (continued)Security to be setReading of devicegroup or copygroup informationCommand d

Página 279

2. LDEV addition to device group3. LDEV deletion from device group4. Device group deletionNote: The following symbols are used in the use cases descri

Página 280

Device group creationCreating a device group by specifying a subject of multiple LDEV IDs and device group names ofthe device groups to be created.• U

Página 281

• Use CasesThe following shows use cases that can be added an LDEV to a device group.◦ Adding an LDEV (simplex volume) with a different device name to

Página 282

LDEV can be deleted from the device group associating a copy group. The pair status does notchange even if the LDEV is deleted from the device group.•

Página 283

Operational notes and restrictions for RAID Manager operations...215Error messages and error codes...

Página 284

from the device, the relevant device group is deleted. And, even if a device group is deleted, thepair status of the pair in the device group does not

Página 285

When creating a copy group• In case of creating a copy group by executing a command, a copy group cannot be createdthrough direct specification of mul

Página 286

Copy group creationSpecifying two device groups and creating a copy group. The same device name must not bedefined for any LDEVs in a specified device

Página 287

With the same device name, the operation for the device group associated with a copy groupcannot be performed.• Use casesThe following shows use cases

Página 288

It is not possible to delete LDEVs directly from the copy group.• Use casesThe following shows use cases that can be deleted LDEVs from the device gro

Página 289

• Use casesA copy group can be deleted even if it is configured of simplex volumes or paired volumes.The following shows use cases that can be deleted

Página 290

If there is no target LDEV to be a pair in the copy group, the process is terminated by detectingan error.86 RAID Manager functions on the P9500 and X

Página 291

• Use casesAs an example of pair operation, the following shows use cases that can be created a pairby specifying a copy group.◦ Creating a pair in ca

Página 292

◦ Creating a pair in cases where the numbers of LDEVs in two device groups in a copygroup configured of simplex volumes are different.In the following

Página 293

For more information about displayed pair status of open LDEVs, see “Continuous AccessSynchronous/Business Copy/Continuous Access Journal pair status”

Página 294

1 OverviewThis chapter provides an overview of the RAID Manager software and RAID Manager operationson the HP RAID storage systems.About RAID ManagerT

Página 295

Table 23 Pair status and access permission for Continuous Access Journal/Continuous AccessJournal Z (continued)NotesAccess tomainframeS-VOLAccess toma

Página 296 - Calling the HP Support Center

Table 25 Operational differences for multiplatform volumesContinuous AccessJournal operationsContinuous AccessSynchronousoperationsBusiness Copy opera

Página 297 - Related information

multi-array virtualization function (XP7 only)The multi-array virtualization function enables you to minimize rewrites of configuration definitionfile

Página 298 - Typographic conventions

Using RAID Manager in a system configuration with the multi-array virtualizationfunctionTo use RAID Manager with the system configuration using the mu

Página 299

Example of the configuration definition files when specifying a virtual storage machine byHORCM_VCMDExample of the configuration definition files (HOR

Página 300 - Glossary

Specifying a virtual storage machine by command optionsConfiguration definition file settings when specifying a virtual storage machine by command opt

Página 301

\\.\CMD-368000:/dev/rdskHORCM_LDEVOra dev1 366000 02:00 h1Ora dev2 366000 02:01 h1#/********** For HORCM_INST **********

Página 302 - 302 Index

RemarksHow to issue the command to the virtual storage machineCommands-p <port> option as "CL1-An"(specify a unit ID in n).The informa

Página 303

Operation target when you specify thevirtual storage machineCommandsOperation typeXP7raidcom add hba_wwnXP7raidcom set hba_wwnXP7raidcom reset hba_wwn

Página 304 - 304 Index

Operation target when you specify thevirtual storage machineCommandsOperation typeXP7raidcom add rcuXP7raidcom delete rcuXP7raidcom add rcu_pathLogica

Comentários a estes Manuais

Sem comentários