Table 36 State table for Continuous Access Synchronous vs. Continuous Access Asynchronous
Transfer
data via
ESCON
Writing control on Cnt Ac-S
async volume
DescriptionDisk array
internal state
RAID
Manager
state
ResponseWriting dataContinuous Access AsynchronousContinuous Access
Synchronous
NoneUsualNormalSameSMPLSMPLSMPL
Sidefile &
bitmap
Usual*Via SidefileSameCOPYCOPYCOPY
SidefileUsualNormalDeleting from COPY using [pairsplit
-S]
N/ADeleting
SidefileUsualVia BitmapSuspending from COPY by using
[pairsplit]
N/ASuspending
SidefileUsualVia SidefileLess than HWMAsync sidefile
in use
SynchronizedPAIRPAIR
SidefileDelayedVia SidefileHWM to ThresholdN/APFUL
SidefileWait until
under
threshold
Via SidefileOver Threshold
SidefileUsualNormalDeleting from PAIR using [pairsplit
-S]
N/ADeleting
SidefileUsualVia BitmapUsing [pairsplit ]Suspending
from PAIR
N/ASuspending
Timeout of over
threshold
NoneUsualVia BitmapSamePSUSPSUSPSUS
NoneUsualVia BitmapTimeout Over ThresholdNonePFUS
NoneUsualVia BitmapSame (link down, etc)PSUEPSUEPSUE
NoneUsualVia BitmapSamePDUBPDUBPDUB
* If the host has more write I/Os in COPY state, then host write I/Os are delayed until there is enough space in the sidefile.
Legend:
Bitmap: Host write data is managed via a cylinder BITMAP of delta data.
Normal: Host write data is not managed by BITMAP or sidefile.
Usual: Host side writing response is not delayed.
HWM (High Water Mark): Sidefile quantity is over 30% of cache storage.
Continuous Access Asynchronous/Continuous Access Journal error state
In the case of an ESCON or fibre-channel (FC) failure, the S-VOL FIFO queue is missing a data
block that was transferred from the P-VOL FIFO queue. The RCU waits to store the next sequenced
data block in the S-VOL FIFO queue until the Continuous Access Asynchronous copy pending
timeout occurs (defined using Continuous Access Synchronous). In addition, the timeout value can
be specified at SVP. The default value is set to 5 minutes. If the timeout occurs during this waiting
state, the pair status changes from PAIR to PSUE, and non-sequenced data blocks are managed
by the S-VOL bitmap. The missing data block can be recovered using the pairresync command,
which merges the S-VOL bitmap with the P-VOL bitmap. Figure 54 (page 165) shows this situation
on the secondary side.
164 Data replication operations with RAID Manager