Table 46 Command error messages (continued)
ValueRecommended actionConditionError
message
Error code
230Please confirm the command name.An unknown command was
attempted.
Unknown commandEX_UNWCMD
229Please confirm the pair status using
the pairdisplay command.
The pair status of a volume
within a group is not
identical to the status of the
other volumes in the group.
Inconsistent status in
group
EX_INCSTG
228Please confirm the pair status using
the pairdisplay command.
The pair status of the target
volume is not appropriate.
Invalid pair statusEX_INVSTP
222Please confirm the volume status
using the pairdisplay -l or the
raidvchkdsp -v aou command.
The volume status of the
target volume is not
appropriate.
Invalid volume statusEX_INVVOL
220Please confirm the MU# (MU #1/2
cannot be used for Continuous
The MU# of the volume to
be operated is not
appropriate.
Invalid mu# with
HORC/UR or
HOMRCF
EX_INVMUN
Access Synchronous and must be
P-VOL for Business Copy.) for the
specified group using the
pairdisplay command. And also
confirm the command execution
environment to be set as HOMRCF.
227Please confirm that the Port, Target
ID, LUN are defined correctly under
A device defined in the
configuration file does not
No such LDEV within
the RAID
EX_ENLDEV
HORCM_DEV in the configuration
file.
have a mapping to a real
LUN and target ID within the
RAID storage system.
226Contact the HP Technical Support.Wrong return code.Invalid return codeEX_INVRCD
225Check the volume list to see if an
operation was directed to the wrong
S-VOL.
Currency check error for
S-VOL. Cannot guarantee
identical data on S-VOL.
S-VOL currency errorEX_VOLCUR
224Please confirm the pair status of the
local volume using the pairdisplay
command.
The volume specified with
the SVOL-takeover command
is not the same as the P-VOL.
Local volume
currency error
EX_VOLCUE
223Please confirm the pair status of
remote and local volumes using the
pairdisplay command.
The combination of the
volumes specified with
Swap-takeover is unsuitable.
Local and remote
volume currency
error
EX_VOLCRE
--Contact the HP Technical Support.Wrong error code.Unknown error
code.
EX_UNWERR
217Please create a pair with cutting the
number of the group on the
When creating Continuous
Access Synchronous
Not enough CT
groups in RAID
EX_ENOCTG
configuration files or make alreadyAsync/UR or Business Copy
existing group and the target groupvolume, CTGID could not be
the same CTGID. Please confirmregistered due to being
already existing group CTGID usingbeyond the max number of
the pairvolchk command. Then,CT groups (0-255 for
P9500, XP24000/XP20000
please create a pair specifying
Disk Array, 0-255 for
CTGID as the paircreate -f
option.
XP12000 Disk
Array/XP10000 Disk Array,
0-127 for XP1024/XP128
Disk Array, 0-15 for XP256
Disk Array) for an async
volume.
222 Troubleshooting