Table 89 SSB codes that are returned by raidcom delete rcu_path command (continued)
raidcom delete rcu_path
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
The operation cannot be done because the number of paths
becomes less than the least path number.
31012E23AsyncGet Command Status
The port attribute is not Initiator (MCU).840A2E30ExecutingCMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
30012E31AsyncGet Command Status
Command cannot be executed because the serial number is not
unified in the specified path.
31012E31AsyncGet Command Status
The command cannot be accepted because the DKC is busy.
After a while, execute the same command.
00EE2ED6ExecutingCMDRJE
An internal error occurred.30052ED6AsyncGet Command Status
Call HP Technical Support.
The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.
30022EF3ExecutingCMDRJE
Table 90 SSB codes that are returned by raidcom add rcu_path command
raidcom add rcu_path
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
CU# of RCU exceeds the effective value.30012E00ExecutingCMDRJE
Invalid product ID or path registration ID.30052E00ExecutingCMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsyncGet Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
30092E00AsyncGet Command Status
The value of port # on the side of RCU is invalid.32002E00ExecutingCMDRJE
The CU number is out of effective range.71002E00ExecutingCMDRJE
/AsyncGet Command Status
The value of specified port is invalid.84002E00ExecutingCMDRJE
/AsyncGet Command Status
Failed to establish a path or the deletion operation. The following
factor can be thought.
31012E10AsyncGet Command Status
• Input parameter is invalid.
• Port status or the MP Blade status is in the state of abnormal.
• Cable is not connected correctly.
• Port is specified incorrectly.
The operation cannot be done because the microcode is being
changed.
80042E11AsyncGet Command Status
The command cannot be accepted. After a while, execute the
same command.
94002E11ExecutingCMDRJE
278 Troubleshooting
Comentários a estes Manuais