Hp XP7 Storage Manual do Utilizador Página 275

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 274
Table 87 SSB codes that are returned by raidcom add thp_pool command (continued)
raidcom add thp_pool
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
Thin Provisioning program product is not installed.90072E21ExecutingCMDRJE
Exceeded the number of pool volume that can be registered in
a pool.
00052E22AsyncGet Command Status
The larger number of drive types than the supported
configuration cannot be added to the specified pool.
000D2E22AsyncGet Command Status
Pool volume cannot be registered because the drive type of
specified LDEV is different from the other pool volume type, or
the drive type in the pool exceeds three.
61002E22AsyncGet Command Status
The number of specified LDEVs is invalid.00082E23ExecutingCMDRJE
The emulation type of specified LDEV cannot be used as a pool
VOL.
00002E30AsyncGet Command Status
The specified LDEV has the LU path definition.00072E30AsyncGet Command Status
The specified LDEV is used as a External Storage Access
Manager quorum disk.
000C2E30AsyncGet Command Status
The specified LDEV is used as a system disk.000D2E30AsyncGet Command Status
The specified LDEV is already used as a pool volume.000E2E30AsyncGet Command Status
The specified LDEV is a command device.00102E30AsyncGet Command Status
It cannot be used as a pool volume because the size of specified
LDEV is less than 8GB.
00382E30AsyncGet Command Status
Creating a pool or adding a pool volume cannot be done
because CLPR is mixed in the specified pool.
00392E30AsyncGet Command Status
The specified LDEV is used as a V-VOL.005C2E30AsyncGet Command Status
The specified LDEV is a volume of unsupported Smart Tiers.005D2E30AsyncGet Command Status
The specified LDEV is used in another program product.005E2E30AsyncGet Command Status
An LDEV, whose emulation type is not available to be mixed,
is in the specified LDEVs.
006C2E30ExecutingCMDRJE
The operation cannot be done for the following reasons:006E2E30AsyncGet Command Status
The pool volumes to be added to the Smart Tiers pool include
external volumes whose cache modes are invalid.
The Thin Provisioning pool includes both external volumes
whose cache modes are invalid and internal volumes.
A pool volume cannot be added because the LDEV of the
resource group different from the resource group of the pool
volume to which the specified pool belongs is specified.
00712E30Executing
Async
CMDRJE
Get Command Status
The specified LDEV cannot be operated because it is an external
volume mapped for online data migration.
00742E30AsyncGet Command Status
The specified volume cannot be used as a pool volume.00852E30AsyncGet Command Status
The threshold value 1 is out of range.60002E30ExecutingCMDRJE
The specified pool attribute differs from the pool attribute of
existed pool.
60042E30AsyncGet Command Status