Table 62 SSB codes that are returned by raidcom add journal command (continued)
raidcom add journal
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
The specified volume is not installed or cannot be used.00112E10ExecutingCMDRJE
AsyncGet Command Status
The specified volume is connected from the mainframe host.001A2E10AsyncGet Command Status
There is a PIN slot in the journal volume.001B2E10ExecutingCMDRJE
AsyncGet Command Status
The specified volume cannot be registered as a journal volume
because it is in shredding. Wait until the shredding operation
is completed, then retry the operation.
001C2E10Executing
Async
CMDRJE
Get Command Status
The specified volume is used in maintenance operation.00532E10AsyncGet Command Status
The specified volume cannot be used as the journal volume
because the virtual LDEV ID is deleted.
00562E10AsyncGet Command Status
The specified volume cannot be used as the journal volume
because it is the virtual volume.
00572E10AsyncGet Command Status
The specified operation failed because the journal or mirror is
not in the operable status.
50002E10AsyncGet Command Status
The operation cannot be done because it is in the state of
start-up.
800B2E11AsyncGet Command Status
The operation cannot be done because the internal processing
is in progress. Wait for a while, then retry the operation.
800E2E11AsyncGet Command Status
Abnormal cache status.810A2E11ExecutingCMDRJE
AsyncGet Command Status
The command cannot be accepted. After a while, execute the
same command.
94002E11ExecutingCMDRJE
The specified LDEV is not defined.00002E20ExecutingCMDRJE
The specified MP Blade is not installed.83002E20ExecutingCMDRJE
The operation failed because the specified journal is not
installed.
50002E21AsyncGet Command Status
The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).
81042E21AsyncGet Command Status
The SM for Continuous Access Journal is not installed.81052E21ExecutingCMDRJE
A journal volume cannot be registered, or a journal cannot be
added to the extended CT group because the program product
90002E21AsyncGet Command Status
of Continuous Access Journal or Continuous Access Journal Z
is not installed.
A new journal volume cannot be registered, or the number of
selected volumes is too many.
00052E23AsyncGet Command Status
The number of specified LDEVs is invalid.00082E23ExecutingCMDRJE
The operation failed because the multiple LDKC numbers cannot
be mixed in the journal.
003E2E23AsyncGet Command Status
The operation failed because the number of journals in the
journal or the extended CT group exceeds the maximum.
50002E23AsyncGet Command Status