Hp XP7 Storage Manual do Utilizador Página 201

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 200
The following example flushes the system buffer associated with all groups for the local instance.
raidscan -pi $Volume -find sync
[SYNC] : ORA ORA_000[-] -> \Vol44\Dsk0 : Volume{56e4954a-28d5
4824-a408-3ff9a6521e5d}
[SYNC] : ORA ORA_000[-] -> \Vol45\Dsk0 : Volume{56e4954a-28d5
4824-a408-3ff9a6521e5e}
[SYNC] : ORB ORB_000[-] -> \Dmt1\Dsk1 : Volume{bf48a395-0ef6
11d5-8d69-00c00d003b1e}
[SYNC] : ORB ORB_001[-] -> \Dmt1\Dsk2 : Volume{bf48a395-0ef6
11d5-8d69-00c00d003b1e}
[SYNC] : ORB ORB_002[-] -> \Dmt1\Dsk3 : Volume{bf48a395-0ef6
11d5-8d69-00c00d003b1e}
NOTE: Windows NT does not support the LDM volume, so specify $LETALL instead of $Volume.
Offline backup using raidscan-find sync for Windows file system:
The raidscan-find sync command flushes the system buffer associated with a logical drive
through finding a Volume{guid} corresponding to a group of the configuration file, without using
the -x mount and -x umount commands. The following examples are for group ORB.
S-VOL SideP-VOL Side
Close all logical drives on the P-VOL by application.
Flush the system buffer for NEW S-VOL data using raidscan
-pi $Volume -find sync -g ORB.
Flush the system buffer for P-VOL using raidscan -pi
$Volume -find sync -g ORB.
Back up the S-VOL data.
Split the paired volume using pairsplit -g ORB with
r/w mode.
Flush the system buffer for S-VOL updates using raidscan
-pi $Volume -find sync -g ORB when the backup is finished.
Open all logical drives on the P-VOL by application.
Resynchronize the paired volume using pairresync
-g ORB.
Online backup using raidscan-find sync for Windows file system:
The raidscan-find sync command flushes the system buffer associated with a logical drive
through finding a Volume{guid} corresponding to a group of the configuration file, without using
the -x mount and -x umount commands. The following examples are for group ORB.
S-VOL SideP-VOL Side
Freeze DB on opening P-VOL by application.
Flush the system buffer for NEW S-VOL data using raidscan
-pi $Volume -find sync -g ORB .
Flush the system buffer for P-VOL using raidscan
-pi $Volume -find sync -g ORB .
Back up the S-VOL data.
Splits the paired volume using pairsplit -g ORB
with r/w mode.
Flush the system buffer for S-VOL updates using raidscan -pi
$Volume -find sync -g ORB when the backup is finished.
Unfreeze DB on opening P-VOL by application.
Resynchronize the paired volume using pairresync
-g ORB.
Offline backup using raidscan-find sync for Windows NT file system:
LDM volume discovery and flushing for Windows 201
Vista de página 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 303 304

Comentários a estes Manuais