9-18
Command Line Interface User’s Guide
2:02:0 64.0KB: 100MB
2:03:0 64.0KB: 100MB
Scrubbing a RAID-5 Set
The CLI allows you to scrub a RAID-5 set. Scrubbing a RAID-5 set
recalculates and replaces, if necessary, the parity information. You
use the container scrub command to scrub a RAID-5 set.
To work with scrubbing a RAID-5 set, you must understand:
The RAID-5 set scrub attributes that you can specify
How to scrub a RAID-5 set
The following sections discuss each of these topics.
Understanding the RAID-5 Set Scrub Attributes You can Specify
You use the container scrub command to scrub a RAID-5 set.
Before scrubbing a RAID-5 set, consider the following attributes you
can specify:
I/O delay
No repair
Wait
Specifying the I/O Delay When Scrubbing a RAID-5 Set
The i/o delay attribute indicates the number of milliseconds the
controller waits between the I/O operations required to scrub the
redundant container. The I/O delay value is not preserved between
operating system reboots. Valid values are 0 through 100.
In the following example, the container scrub command with
the /io_delay switch sets the delay to 10 milliseconds.
HPN0> container scrub /io_delay=10 2
Executing: container scrub /io_delay=10 2
Specifying No Repair when Scrubbing a RAID-5 Set
The no repair attribute indicates if the scrub operation repairs
errors if they are encountered.
In the following example, the container scrub command with
the /no_repair switch repairs errors if they are encountered.