11-9
Working with Diagnostic Commands
time is set to 20 milliseconds (that is, 20 milliseconds = 200 x 100
microseconds).
HPN0> diagnostic moderation show timer
Executing: diagnostic moderation show Timer
The moderation timer is currently set to 200.
Loading Containers
When in maintenance mode, you use the diagnostic
load_containers command to load containers and partition
tables from the disks into the controller’s memory. If any disk
partition structures have changed, this command causes those
changes to be reflected in the container and partition lists in the
controller memory. If you add disks to the controller, the
diagnostic load_containers command enables you to use
those disks.
The diagnostic load_containers command is similar to the
controller rescan command, except that it does not rescan
SCSI channels. See Rescanning a Controller on page 3-12 for
information on the controller rescan command.
To load containers, use the diagnostic load_containers
command, as in the following example. In the example, the All boot
time parameters cleared to default values line indicates that all boot
time parameters have been cleared to the default values.
HPN0> diagnostic load containers
Executing: diagnostic load_containers
All boot time parameters cleared to default values.