When connecting the power cables, use the power cables shipped with the EVA. After power is
supplied to the EVA, the power supply automatically senses the input voltage and the power supply
LED illuminates as solid amber.
Table 2 Power cable connections
Level of ProtectionConnection Method
Protects you from downtime when one of the EVA power supplies fails.
The remaining power supply/fan module can operate the EVA until you
install a replacement module.
EVA power supplies connected
to one power source
Protects you from downtime when one of the EVA power supplies fails.
Protects you from data loss when one of your power sources fails, due to
a pulled cable or tripped breaker.
The remaining power source can power the EVA until the failed power
source is restored or relocated.
Depending on the cause and duration of the power outage, you can use
this time to properly shut down your storage sub-system.
EVA power supplies connected
to two separate power sources
Protects you from downtime when one of the EVA power supplies fails.
Protects you from data loss when one or both of your power sources fails,
due to a pulled cable, tripped breaker, or local power outage.
The remaining power source or the UPS will power the EVA until power is
restored to the source. Depending on the cause and duration of the power
outage, you can use this time to properly shut down your storage sub-system.
EVA power supplies connected
to:
• Two uninterruptible power
supplies
• Two separate power sources
For more information about power sources, see the HP StorageWorks 4400 Enterprise Virtual Array
User Guide.
HP StorageWorks 4400 Enterprise Virtual Array Installation Guide 27