Write 1GB of data for DAT72 and below and 2GB of data for DAT160 and above and then
measures the write margin.
Read 1GB of data for DAT72 and below and 2GB of data for DAT160 and above and then
measures the read margin.
1/8 Autoloader Assessment tests performed:
Review robotics error log entries.
Run appropriate drive assessment test on the drive.
Check for new robotics error log entries.
Perform 12 to 24 drive loads and unloads (depending on drive type)
Check for new robotics error log entries.
Options
Enable Passive Test (defaults to TRUE)—Analyzes drive history (runs device
analysis and looks at DDS Reports information).
Allow overwrite(defaults to FALSE)—Set to TRUE to avoid the pop-up warning
about erasing data on the tape.
Ignore Cleaning Requests (defaults to FALSE) —When TRUE the test will
not check whether the drive is requesting cleaning
Amount of Media to Test (defaults to 1GB for DAT72 and below and 2GB for
DAT160 and above)—Select the entire tape to test all of the tape.
Number of Iteration (default is one) – Number of times to run the write portion
of the test.
DLT, DLT1, VS80, VS160, and SDLT Assessment tests performed:
SCSI interconnect test
Review event log entries (that were present prior to running this test)
Load the test tape
Quick write/read test
Soft unload/load test (DLT assessment test only)
Minimum block size test
Diagnostic Self-test (built-in drive function)
Read/write tests, using various data patterns
Bit error rate test
Review new event log entries added during the test
Unload the test tape
Performance tests 105