Fault Isolation 4-65
Continue on with Step 3, Step 4, or Step 5, depending on the configuration of the dc
output voltages.
3. If the dc output voltages are not present at J004, perform the following steps:
A. Check the ac outlet for power with a voltmeter. If the ac outlet power is
incorrect, an electrician must correct it.
B. With the power-on switch open, use a voltmeter to check Pin 8 on the J004
connector for +16 to + 20 V dc. If the voltage is not correct, replace the
power supply.
If the voltage is correct at Pin 8, close the power-on switch. If you read Pin
8 at ground, replace the power supply. If you still detect +16 to + 20 V dc,
replace the power-on switch panel. If the new switch doesn’t fix the prob
-
lem, replace these FRUs in the following order:
Ribbon Cable (connects LED board to CPU board)
LED Board
CPU Board
You can check these FRUs before you replace them by checking the pow-
er-on switch circuits for continuity as shown in Table 4-18. Check for con-
tinuity with Connectors J004 and J002 unplugged. Refer to Figure 4-18 for
the locations of the connectors and pins listed in Table 4-18.
Table 4-18. Switch Circuit FRU Pin Numbers
To Check This FRU Check for Continuity Between
These Two Connectors
FRU
CPU Board
Cable from LED Board to CPU Board
LED Board
CPU Board
Cable from LED Board to CPU Board
LED Board
Connector Pin to Connector Pin
J004 8 J001 15
J001 15 J001 15
J001 15 J002 4
J004 20
J001 1
J001 1
J001 1
J001 1
J002 3
Vista de página 134