Confi guring the EEPROM C-17
C.4.3 Using the Control Functions
Your Configurable Interfaces menu has three control functions
N store New values
D store Default values
(then cycle SPU power)
A Abort without changes
N saves all listed interfaces reconfigured values in the EEPROM. You can turn
OFF your system unit, then turn it back ON and the values you configured the
interfaces to are used. Then the self-test runs.
D exits the Configuration Mode and resets the factory default configurations.
You must cycle system unit power to reconfigure the interfaces to these default
values.
A causes the Boot ROM to reset and run the self-test without saving any new
interface configurations you may have made. The interfaces existing configu
-
rations are used.
If the Boot ROM or EEPROM has problems after you enter N or D, the mode lines
display one of the error messages shown in the following table.
Table C-6. Configuration Mode Exit Error Messages
Command Error Message Meaning and What To Do
N or D
N or D
N or D
A
Too many configuration saves
Can not save new configuration
EEPROM can not save information
(No message should appear)
More than 64,000 saves were tried.
Unlikely to occur.
Something prevented saving the new
configuration. Hardware failure.
Replace CPU board.
EEPROM may not save any or all of
the new configuration information.
Hardware failure. Replace CPU
board.
No error messages should appear