SCSI-2 Drive Command Set
Read (Group 5) Command (A8H)
Chapter 2 2-129
SCSI-2 Drive Commands
DPO A Disable Page Out bit of 1 instructs the target not to
store readahead data in cache after the read data has
been transferred to the initiator.
A DPO bit of 0 instructs the target it may store
readahead data in the cache after the read data has
been transferred to the initiator.
NOTE The DPO bit is ignored in 9.1 and 5.2 Gbyte capacity drives.
FUA A Force Unit Access bit of 1 indicates that the drive
reads from the disk.
An FUA bit of 0 indicates that data may come from the
cache memory.
Rel Adr A relative address bit of one indicates that logical block
address specified is a two’s complement offset from the
last logical block address accessed.
A value of 0 indicates that the logical block address is an
absolute address.
Transfer
Length The Transfer Length field specifies the number of
contiguous logical blocks of data to be transferred.
A value of 0 indicates that no blocks will be transferred
and is not considered an error.
PBA A Physical Block Address bit of 1 indicates that physical
block addressing is used.
A PBA bit of 0 indicates that logical block addressing is
used.
NOTE For Write-Once optical disks, blank checking is performed following a
failed read. If the sector is blank, the sense key/additional sense code will
be set to BLANK CHECK/Blank Sector Detected.