Autochanger Error Codes
Request Sense Error Codes
Appendix B B-5
Autochanger Error Codes
22 00H 5H-IR Unsupported command
22 80H 5H-IR Drive is not online
24 00H 5H-IR Illegal field in CDB
25 00H 5H-IR Invalid LUN
26 00H 5H-IR Invalid parameter list
29 00H 6H-UA Power on sense or bus reset
2A 80H 6H-UA Online repair parameters
2F 00H 0BH-AC Command cleared by initiator
3F 01H 06H-UA Microcode has been changed
3B 0DH 5H-IR Element full - (Table B-4 on page B-7)
3B 0EH 5H-IR Source empty - (Table B-4 on page B-7)
3D 00H 5H-IR Invalid identify message in
3F 03 06-UA Inquiry data has changed
40 80H 4H-HE Diagnostic failure (Table B-6 on page B-14)
42 00H 4H-HE Poweron selftest failure
43 00H OB-AC Message parity error
44 00H 4H-HE Internal target error
45 00H 0B-AC Reselection timeout error
47 00H 0B-AC Parity error
48 00H 0B-AC Initiator detected error
4B 00H 0B-AC Bus protocol error - data phase error
Table B-2 Request Sense Data (bytes 12 and 13)
Sense
Code
and
Qualifier
Sense
Key
Description