Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix BB-50
43
Mailslot Sensor Test
(Interactive if done
through the control
panel)
See the description for Test 42.
44
Cartridge-in-path
(Interactive if done
through the control
panel)
Displays max/min intensity and ambient
readings for the left and right beams. You must
enter a parameter to choose the beam to display
(0=left, 1=right). The following is an example of
an error message for the right beam and how it
is translated:
F0 is hexadecimal for 240
E1 is hexadecimal for 225
R means right beam
06 is the maximum ambient reading.
00 is the minimum ambient reading.
Intensity L/R Ambient
Max Min Max Min
240 225 R 6 0
Press
CANCEL to stop.
50
Find Home Sequence 50Find Home SequenceMoves the picker to a
known "home" position. This test assumes
nothing about the state of the mechanics. The
"home" location is the lower left position of the
box. The servo system is initialized to the "home"
location. It then automatically runs Test 51.
51
Carriage/Picker
Assembly Calibration
Test
Runs the portion of the mechanism recalibration
related to the optical sensors. It measures sensor
offsets and calculates picker tilt and droop. This
test assumes that the mechanics and servo
system are functional.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)