Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix BB-40
Diagnostic Tests
The following tables describe the optical disk library diagnostic tests for
all models, EXCEPT for 40fx, 80ex, 125ex, and 220mx jukeboxes. See
Table B-13 on page B-44 for diagnostic tests for the 40fx, 80ex, 125ex,
and 220mx models.
CAUTION Some diagnostic tests can result in a disk being placed into an improper
storage slot. If this happens, the optical disk library file system is no
longer accurate.
NOTE Not all tests listed in Table 5-12 on page 5-39 are supported on all HP
jukebox models.
Table B-12 Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and
220mx)
No. Front Panel
Test Name
Description
1
POWER UP
TEST
Checks out the general capability of jukebox
by running
INIT MECHANICS test.
2 WELLNESS
TEST
Checks out the general capability of the
jukebox by running the
INIT MECHANICS and
EXERCISE MECH tests. Requires one loaded
cartridge; drive and mailslot must be empty.
5
INIT
MECHANICS
Runs the FIND PLUNGE HOME, FIND VERTICAL
HOME
, FIND XLATE HOME, and the INIT ELEM
STATUS
tests, and rotates the mailslot out.
10
INIT ELEM
STATUS
Functions the same as the SCSI Initialize
Element Status command. This test
physically scans the entire unit to determine
which storage slots contain disks and if the
drives contain disks.
11
EXERCISE
MECH
Runs VERTICAL TEST, TRANSLATE TEST, FLIP
TEST
, MAGAZINE IO, DRIVE IO, and MAILSLOT
IO
tests.