Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix B B-47
Autochanger Error Codes
16 Drive I/O Test Performs a combination of moves with a pass/fail
result. It moves a cartridge from a randomly-
chosen full slot to a drive, with a random flip. It
then moves the cartridge back to its original slot
with its original orientation. It does this once for
each optical drive. Returns an error code #57H
Invalid Configuration if there are no cartridges
loaded into the unit. Requires one loaded
cartridge; drives must be empty.
17
Mailslot I/O Performs a combination of moves with a pass/fail
result. It moves a cartridge from the lowest-
numbered full slot to the mailslot with a random
flip. It then moves the cartridge back to its
original slot with its original orientation.
Returns an error code #57H Invalid
Configuration if there are no cartridges loaded
into the unit. Requires one loaded cartridge;
mailslot must be empty.
18
Speed Factor Setting
Utility
Allows the setting of the speed factor as the first
parameter given. The speed factor determines
how fast the system moves the mechanics. The
number provides 1/Parameter speed (e.g.
Parameter=3 runs the motors at 1/3 of full
speed). This test can only be run from the SCSI
Interface.
19
Zero Maximum Force
Log
The maximum force log is initialized to all zeros.
20
Set Speed Factor to
Full Speed
Allows the mechanics to be run at full speed.
21
Set Speed Factor to
Half Speed
Allows the mechanics to be run at half speed.
22
Set Speed Factor to
Quarter Speed
Allows the mechanics to be run at quarter speed.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)