Página 1 - 3.1.x/4.1.x

user guidehp StorageWorksfabric OS procedures version3.1.x/4.1.xProduct Version: V3.1.x/V4.1.xThird Edition (June 2003)Part Number: AA–RS23C–TEThis

Página 2 - Part Number: AA–RS23C–TE

Contents10 Fabric OS Procedures Version 3.1.x/4.1.x User GuideTest a Switches Internal Components . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 3

Basic Security in FOS100 Fabric OS Procedures Version 3.1.x/4.1.x User Guide4. Repeat for all switches in the fabric. Note: You cannot change account

Página 4

Basic Security in FOS101Fabric OS Procedures Version 3.1.x/4.1.x User Guide1) Start system.2) Recovery password.3) Enter command shell.4. Enter “2” at

Página 5

Basic Security in FOS102 Fabric OS Procedures Version 3.1.x/4.1.x User Guide3) Enter command shell.5. Enter “2” at the prompt to set the Recovery pass

Página 6

Basic Security in FOS103Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: Setting the Boot PROM password requires accessing the boot prompt, w

Página 7

Basic Security in FOS104 Fabric OS Procedures Version 3.1.x/4.1.x User Guide5. Enter passwd command at the prompt.Note: This command is specific to t

Página 8

Basic Security in FOS105Fabric OS Procedures Version 3.1.x/4.1.x User Guide4. Reboot the standby CP card by pressing the yellow ejector buttons at top

Página 9

Basic Security in FOS106 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAbout Forgotten PasswordsPasswords can be recovered as follows: If the Us

Página 10 - Contents

Basic Security in FOS107Fabric OS Procedures Version 3.1.x/4.1.x User GuideA: The end-user is prompted to use the old password when the account is bei

Página 11

Basic Security in FOS108 Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Página 12

109Fabric OS Procedures Version 3.1.x/4.1.x User Guide5Working With the Core Switch 2/64This chapter provides information on working with the Core Swi

Página 13 - Initial Configuration

Contents11Fabric OS Procedures Version 3.1.x/4.1.x User Guide9 16-Port Count Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 14 - Configuring the IP Addresses

Working With the Core Switch 2/64110 Fabric OS Procedures Version 3.1.x/4.1.x User GuidePorts on the Core Switch 2/64In previous versions of the Fabri

Página 15

Working With the Core Switch 2/64111Fabric OS Procedures Version 3.1.x/4.1.x User GuideCFigure 1: Graphic Illustration of Core Switch 2/64About the S

Página 16

Working With the Core Switch 2/64112 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: No spaces are allowed between the slot number, the slas

Página 17

Working With the Core Switch 2/64113Fabric OS Procedures Version 3.1.x/4.1.x User GuideExampleswitch:admin> switchshowswitchName: switchswitchT

Página 18

Working With the Core Switch 2/64114 Fabric OS Procedures Version 3.1.x/4.1.x User Guide 11 1 11 -- N2 No_Module 12 1 12 id N2

Página 19 - Initial Setup Example

Working With the Core Switch 2/64115Fabric OS Procedures Version 3.1.x/4.1.x User GuideBasic Blade ManagementFor the purposes of this section, Basic B

Página 20

Working With the Core Switch 2/64116 Fabric OS Procedures Version 3.1.x/4.1.x User GuideEnabling a BladeTo enable a blade unit. 1. Log into the switch

Página 21 - Switch Login

Working With the Core Switch 2/64117Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe blade must be disabled so that processing stops. Refer to “

Página 22

Working With the Core Switch 2/64118 Fabric OS Procedures Version 3.1.x/4.1.x User GuideCore Switch 2/64 ChassisChassis-wide commands display or contr

Página 23

Working With the Core Switch 2/64119Fabric OS Procedures Version 3.1.x/4.1.x User GuideFor complete information about switch FRUs, refer to the Core S

Página 24 - Customize the Switch Name

Contents12 Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Página 25 - Manage Licensed Features

Working With the Core Switch 2/64120 Fabric OS Procedures Version 3.1.x/4.1.x User Guide— Object ID and object number. Valid values include the follow

Página 26 - Verifying License Activation

Working With the Core Switch 2/64121Fabric OS Procedures Version 3.1.x/4.1.x User GuideExampleswitch:admin> chassisshowSW BLADE Slot: 1Header Vers

Página 27

Working With the Core Switch 2/64122 Fabric OS Procedures Version 3.1.x/4.1.x User GuidePower Consume Factor: -40Brocade Part Num: 65-0000555-

Página 28 - Configure Fabric Parameters

Working With the Core Switch 2/64123Fabric OS Procedures Version 3.1.x/4.1.x User GuideBlade Beacon ModeWhen beaconing mode is enabled, the port LEDs

Página 29

Working With the Core Switch 2/64124 Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Página 30 - Configure Software Features

125Fabric OS Procedures Version 3.1.x/4.1.x User Guide6The SAN Management ApplicationThis chapter provides the following information: The Management

Página 31 - Verify Switch Function

The SAN Management Application126 Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe Management ServerThis chapter provides information on working

Página 32

The SAN Management Application127Fabric OS Procedures Version 3.1.x/4.1.x User Guidefabric for management purposes; it contains interconnect informati

Página 33 - Connect ISLs to Switch

The SAN Management Application128 Fabric OS Procedures Version 3.1.x/4.1.x User GuideConfiguring Access to the Management ServerAn Access Control List

Página 34

The SAN Management Application129Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. At the command line enter the msconfigure command. The command

Página 35 - Connect Devices to the Switch

13Fabric OS Procedures Version 3.1.x/4.1.x User Guide1Initial ConfigurationThis chapter provides information on initial configuration tasks for a swit

Página 36

The SAN Management Application130 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDeleting a WWN from the Access Control ListTo delete a WWN from t

Página 37

The SAN Management Application131Fabric OS Procedures Version 3.1.x/4.1.x User Guide3. At the select prompt enter 3 to delete a member based on its Po

Página 38

The SAN Management Application132 Fabric OS Procedures Version 3.1.x/4.1.x User GuideMS Access List consists of (13): { 20:00:00:20:37:65:ce:aa 20:00:

Página 39 - Basic Switch Management

The SAN Management Application133Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisplaying the Management Server DatabaseTo view the contents of t

Página 40 - Disabling a Switch

The SAN Management Application134 Fabric OS Procedures Version 3.1.x/4.1.x User GuideClearing the Management Server DatabaseTo clear the MS Platform d

Página 41 - Disabling a Port

The SAN Management Application135Fabric OS Procedures Version 3.1.x/4.1.x User GuideActivating the Platform Management ServiceTo activate the Platform

Página 42 - Example: Core Switch 2/64

The SAN Management Application136 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDeactivating the Platform Management ServiceTo deactivate the Pla

Página 43 - Enabling a Port

The SAN Management Application137Fabric OS Procedures Version 3.1.x/4.1.x User GuideControlling the Topology DiscoveryThe Topology Discovery is an ind

Página 44 - Example: SAN Switch 2/32

The SAN Management Application138 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisable the MS Topology Discovery FeatureDisabling the MS Topolog

Página 45

139Fabric OS Procedures Version 3.1.x/4.1.x User Guide7Updating Switches to the Core PID AddressingFor detailed information regarding migrating to lar

Página 46

Initial Configuration14 Fabric OS Procedures Version 3.1.x/4.1.x User GuideConnecting and Configuring the Switch Perform the following tasks when init

Página 47 - Domain IDs

Updating Switches to the Core PID Addressing140 Fabric OS Procedures Version 3.1.x/4.1.x User GuideOverviewCore PID addressing is an option of the con

Página 48 - Setting a Domain ID

Updating Switches to the Core PID Addressing141Fabric OS Procedures Version 3.1.x/4.1.x User GuideFigure 2: Switch Update Requirements

Página 49 - Firmware Versions

Updating Switches to the Core PID Addressing142 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDetermining If You Need to Enable the Core PIDUse t

Página 50

Updating Switches to the Core PID Addressing143Fabric OS Procedures Version 3.1.x/4.1.x User GuideAbout Core PID AddressingUpdating the Core Switch PI

Página 51 - Switch Date and Time

Updating Switches to the Core PID Addressing144 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAbout Fibre Channel AddressingThere are two address

Página 52

Updating Switches to the Core PID Addressing145Fabric OS Procedures Version 3.1.x/4.1.x User GuideRecommendationsRedundant fabrics and multi-pathing s

Página 53 - Fabric Configuration Settings

Updating Switches to the Core PID Addressing146 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: It is recommended not to use drivers that bi

Página 54

Updating Switches to the Core PID Addressing147Fabric OS Procedures Version 3.1.x/4.1.x User Guide Detailed Update Procedures for HP/UX and AIX provi

Página 55

Updating Switches to the Core PID Addressing148 Fabric OS Procedures Version 3.1.x/4.1.x User GuideEvaluate the FabricThe fabric must be evaluated to:

Página 56

Updating Switches to the Core PID Addressing149Fabric OS Procedures Version 3.1.x/4.1.x User GuideMake List of Manually Configurable PID DriversSome d

Página 57 - Switch Names

Initial Configuration15Fabric OS Procedures Version 3.1.x/4.1.x User Guide7. At the Gateway Address prompt, enter the IP address of the gateway system

Página 58 - Switch Status Policies

Updating Switches to the Core PID Addressing150 Fabric OS Procedures Version 3.1.x/4.1.x User GuideIt is also important to understand how multi-pathin

Página 59

Updating Switches to the Core PID Addressing151Fabric OS Procedures Version 3.1.x/4.1.x User GuidePlanning the Update ProcedureWhether it is best to p

Página 60

Updating Switches to the Core PID Addressing152 Fabric OS Procedures Version 3.1.x/4.1.x User Guide5. Change the PID format on each switch in the fabr

Página 61

Updating Switches to the Core PID Addressing153Fabric OS Procedures Version 3.1.x/4.1.x User Guide9. For any devices manually bound by PID, bring the

Página 62

Updating Switches to the Core PID Addressing154 Fabric OS Procedures Version 3.1.x/4.1.x User GuideProcedures for Updating the Core PID FormatThe foll

Página 63 - Tracking Switch Changes

Updating Switches to the Core PID Addressing155Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:10. Once all switches are updated to use the

Página 64

Updating Switches to the Core PID Addressing156 Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. If you are not using multi-pathing software, sto

Página 65

Updating Switches to the Core PID Addressing157Fabric OS Procedures Version 3.1.x/4.1.x User Guide14. Import the volume groups using vgimport. The pro

Página 66 - Using Dynamic Load-Sharing

Updating Switches to the Core PID Addressing158 Fabric OS Procedures Version 3.1.x/4.1.x User Guide19. Validate that the entry has been removed by usi

Página 67

Updating Switches to the Core PID Addressing159Fabric OS Procedures Version 3.1.x/4.1.x User Guidermdev -Rdl fcs07. Log into each switch in the fabric

Página 68

Initial Configuration16 Fabric OS Procedures Version 3.1.x/4.1.x User Guide8. Enter the ippaddrset command to verify the data you entered, and exit.9.

Página 69

Updating Switches to the Core PID Addressing160 Fabric OS Procedures Version 3.1.x/4.1.x User GuideFrequently Asked QuestionsQ: What is a PID?A: A PID

Página 70

161Fabric OS Procedures Version 3.1.x/4.1.x User Guide8Diagnostics and StatusFor detailed diagnostics information, refer to the HP StorageWorks Diagno

Página 71 - Help Commands

Diagnostics and Status162 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDiagnostics OverviewThe purpose of the diagnostic subsystem is to evaluat

Página 72 - Additional Help Topics

Diagnostics and Status163Fabric OS Procedures Version 3.1.x/4.1.x User GuideThere are two basic modes in which diagnostics can be manually run; they a

Página 73 - Hexadecimal Port Diagrams

Diagnostics and Status164 Fabric OS Procedures Version 3.1.x/4.1.x User Guide statsclear diagshow diagstatus diagreset diagcommandshow diaghelp

Página 74 - 7 = 0111 F = 1111

Diagnostics and Status165Fabric OS Procedures Version 3.1.x/4.1.x User GuidePersistent Error Log The Persistent Error Log feature prevents messages of

Página 75 - Firmware Download

Diagnostics and Status166 Fabric OS Procedures Version 3.1.x/4.1.x User Guide Options are provided to the errdump command to display three options: a

Página 76 - About Firmware Downloads

Diagnostics and Status167Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisplaying the Error Log With Page BreaksTo display the error log:1. Log i

Página 77

Diagnostics and Status168 Fabric OS Procedures Version 3.1.x/4.1.x User GuideIf no operand is specified, this command changes the way the error log ap

Página 78 - The Firmware Upgrade Process

Diagnostics and Status169Fabric OS Procedures Version 3.1.x/4.1.x User GuideExampleThe following example shows how to display current error log save l

Página 79

Initial Configuration17Fabric OS Procedures Version 3.1.x/4.1.x User Guide— Ethernet Subnetmask—Hostname— Gateway IP Address2. Log in to the switch as

Página 80

Diagnostics and Status170 Fabric OS Procedures Version 3.1.x/4.1.x User GuideShowing the Current Persistent (Non-Volatile) Error Log Configuration of

Página 81

Diagnostics and Status171Fabric OS Procedures Version 3.1.x/4.1.x User GuideSyslog DaemonThe Fabric OS can be configured to use a UNIX style syslog da

Página 82

Diagnostics and Status172 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch 2/64 uses the kernel logging facility. The word “kernel” is the na

Página 83

Diagnostics and Status173Fabric OS Procedures Version 3.1.x/4.1.x User GuideSyslogd CLI CommandsBelow is a list of commands that are related to the sy

Página 84 - 4.0.0c or less

Diagnostics and Status174 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExampleThe following entry in /etc/syslog.conf causes all messages (Debug

Página 85

Diagnostics and Status175Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisabling syslogd on the Core Switch 2/64 or SAN Switch 2/32To disable sen

Página 86

Diagnostics and Status176 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch DiagnosticsThe switch status can be either Healthy/OK, Marginal/Wa

Página 87

Diagnostics and Status177Fabric OS Procedures Version 3.1.x/4.1.x User Guide12.1 = SAN Switch 2/3216.2 = SAN Switch 2/8 EL— switchstate - Displays the

Página 88

Diagnostics and Status178 Fabric OS Procedures Version 3.1.x/4.1.x User Guide.For more information, refer to the switchshow command in the HP StorageW

Página 89

Diagnostics and Status179Fabric OS Procedures Version 3.1.x/4.1.x User Guide. 1 1 1 id N2 No_Light Disabled 2 1 2 -- N2 No

Página 90

Initial Configuration18 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Configuring a Logical Switch IP Address for the Core Switch 2/641.

Página 91

Diagnostics and Status180 Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe output will appear different on a SAN Switch 2/32 switch. For more in

Página 92

Diagnostics and Status181Fabric OS Procedures Version 3.1.x/4.1.x User GuidePort DiagnosticsThere are two types of statistics you can view for a port:

Página 93 - New Features

Diagnostics and Status182 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:switch:admin> portshow 3/7portCFlags: 0x1 ENABLEDportFlags: 0

Página 94

Diagnostics and Status183Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: For more information on the portshow command, refer to the HP Stora

Página 95 - Listeners

Diagnostics and Status184 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Note: For more information on the portstatsshow command, refer t

Página 96

Diagnostics and Status185Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisplaying a Summary of Port ErrorsThis porterrshow command displays a sum

Página 97 - Passwords

Diagnostics and Status186 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: For more information on the porterrshow command, refer to the HP S

Página 98 - Switch Access:

Diagnostics and Status187Fabric OS Procedures Version 3.1.x/4.1.x User GuideHardware DiagnosticsFor detailed hardware information, refer to the switch

Página 99 - Managing Passwords

Diagnostics and Status188 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: The number of fans and valid range for RPMs varies depending on th

Página 100 - Setting Recovery Passwords

Diagnostics and Status189Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: The number of power supply units varies depending on the type of sw

Página 101 - Basic Security in FOS

Initial Configuration19Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Initial Setup ExampleThe following example shows an initial setup of

Página 102

Diagnostics and Status190 Fabric OS Procedures Version 3.1.x/4.1.x User Guide crossPortTest portLoopbackTest sramRetentionTest turboRamTest stats

Página 103

Diagnostics and Status191Fabric OS Procedures Version 3.1.x/4.1.x User GuideLinux Root CapabilitiesYou can enable Linux root capabilities for diagnost

Página 104

Diagnostics and Status192 Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Página 105

193Fabric OS Procedures Version 3.1.x/4.1.x User Guide9TroubleshootingThis chapter provides information on troubleshooting and the most common procedu

Página 106 - Frequently Asked Questions

Troubleshooting194 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAbout TroubleshootingTroubleshooting should begin at the center of the SAN — the

Página 107

Troubleshooting195Fabric OS Procedures Version 3.1.x/4.1.x User GuideFibre Channel ProcessFigure 3: Fibre Channel Process Flow Chart

Página 108

Troubleshooting196 Fabric OS Procedures Version 3.1.x/4.1.x User GuideMost Common Problem AreasThere are many tools available to help troubleshoot the

Página 109 - Switch 2/64

Troubleshooting197Fabric OS Procedures Version 3.1.x/4.1.x User GuideHosts Host adaptor LEDsHost operating system diagnostic toolsDevice driver diagno

Página 110 - Ports on the Core Switch 2/64

Troubleshooting198 Fabric OS Procedures Version 3.1.x/4.1.x User GuideGathering Information for Technical SupportTo aid in troubleshooting, gather as

Página 111 - About the Slot/Port Method

Troubleshooting199Fabric OS Procedures Version 3.1.x/4.1.x User GuideSpecific ScenariosThe following sections provide specific help with some of the m

Página 112

© Copyright 1999-2003 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with regard to this material, inc

Página 113

Initial Configuration20 Fabric OS Procedures Version 3.1.x/4.1.x User Guideswitch:admin> ipaddrsetSwitch number [0 for switch0, 1 for switch1, 2 fo

Página 114

Troubleshooting200 Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck the Simple Name Server (SNS)Check for the Device in the SNS1. Enter the ns

Página 115 - Basic Blade Management

Troubleshooting201Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. Look for the device in the list of the Simple Name Server (SNS). The SNS lists

Página 116 - Powering Off a Blade

Troubleshooting202 Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck for Zoning DiscrepanciesTo determine if zoning might be causing a communic

Página 117

Troubleshooting203Fabric OS Procedures Version 3.1.x/4.1.x User GuideFabric SegmentationPossible CausesFabric Segmentation is generally caused by: I

Página 118 - Core Switch 2/64 Chassis

Troubleshooting204 Fabric OS Procedures Version 3.1.x/4.1.x User Guide Long Distance Fabric BB Credit Core PIDDomain ID ConflictsA Domain ID confli

Página 119 - ■ UNKNOWN

Troubleshooting205Fabric OS Procedures Version 3.1.x/4.1.x User GuideRestore Fabric Parameters Through ConfigUploadThe following procedure describes h

Página 120

Troubleshooting206 Fabric OS Procedures Version 3.1.x/4.1.x User Guide5. Chose the fabric on which to change the duplicate Domain ID; log into the con

Página 121

Troubleshooting207Fabric OS Procedures Version 3.1.x/4.1.x User GuideRefer to the HP StorageWorks Zoning Version 3.1.x/4.1.x User Guide for informatio

Página 122

Troubleshooting208 Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. Enter the cfgDisable command.3. Enter the cfgClear command.Caution: Be caref

Página 123 - Blade Beacon Mode

Troubleshooting209Fabric OS Procedures Version 3.1.x/4.1.x User Guide9. Compare the two fabric zone configurations line by line and look for incompati

Página 124

Initial Configuration21Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch LoginThe following sections describe logging into a switch and changi

Página 125 - Application

Troubleshooting210 Fabric OS Procedures Version 3.1.x/4.1.x User Guidesupplier. When MQ errors are encountered, execute the supportShow command to cap

Página 126 - The Management Server

Troubleshooting211Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck the power supply status. Refer to the HP StorageWorks Fabric OS Version 3.1

Página 127

Troubleshooting212 Fabric OS Procedures Version 3.1.x/4.1.x User GuideDevice Login IssuesIn narrowing down problems with device logins, use the follow

Página 128 - Example:

Troubleshooting213Fabric OS Procedures Version 3.1.x/4.1.x User Guide3. Enter the portconfigShow command to see how the port is configured. Example:sw

Página 129

Troubleshooting214 Fabric OS Procedures Version 3.1.x/4.1.x User Guide4. Enter the portErrShow command. Check for errors that may cause login problems

Página 130 - To delete a WWN from the ACL:

Troubleshooting215Fabric OS Procedures Version 3.1.x/4.1.x User Guide5. Enter the portFlagsShow command to see how a port has logged in and where a lo

Página 131

Troubleshooting216 Fabric OS Procedures Version 3.1.x/4.1.x User GuideWatchdog (Best Practices)Watchdog is a subset of the Kernel Error Reporting Soft

Página 132

Troubleshooting217Fabric OS Procedures Version 3.1.x/4.1.x User GuideKernel Software Watchdog Related Errors This section describes the kernel softwar

Página 133

Troubleshooting218 Fabric OS Procedures Version 3.1.x/4.1.x User GuideIdentifying Media-Related IssuesUse the following section to narrow down media-r

Página 134

Troubleshooting219Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck Switch ComponentsThe following sections describe how to troubleshoot the sw

Página 135

Initial Configuration22 Fabric OS Procedures Version 3.1.x/4.1.x User GuideChanging the Admin Password in v3.1 FirmwareFor security reasons, the first

Página 136

Troubleshooting220 Fabric OS Procedures Version 3.1.x/4.1.x User Guide— To check all switches attached components (on an FC loop), see “Check All Swit

Página 137

Troubleshooting221Fabric OS Procedures Version 3.1.x/4.1.x User GuideTest a Port’s External Transmit and Receive Path1. Log into the switch as admin.

Página 138 - *MS feature is disabled

Troubleshooting222 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Test a Switches Internal ComponentsTo use the crossporttest command to t

Página 139 - PID Addressing

Troubleshooting223Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe following example executed fPortTest 100 times on port 8 with payload pattern

Página 140 - Overview

Troubleshooting224 Fabric OS Procedures Version 3.1.x/4.1.x User Guide8. Determine if any of the following statistic error counters are non-zero: ENC_

Página 141

Troubleshooting225Fabric OS Procedures Version 3.1.x/4.1.x User GuideERR_STAT_C3DISCERR_STAT_CRCERR_STAT_ENCINERR_STAT_ENCOUTERR_STAT_TRUNCFDET_PERRFI

Página 142 - Example Scenarios

Troubleshooting226 Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. Disable the switch by entering switchdisable at the command line. 3. Enter po

Página 143 - About Core PID Addressing

Troubleshooting227Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck all Switch Components of the Port Transmit and Receive PathThe following pr

Página 144

Troubleshooting228 Fabric OS Procedures Version 3.1.x/4.1.x User Guide14. Repeat steps 6 - 12 for all ports until:— the number of frames requested is

Página 145 - Recommendations

Troubleshooting229Fabric OS Procedures Version 3.1.x/4.1.x User GuideLink FailureA link failure occurs when a server or storage is connected to a swit

Página 146 - About PID Mapping

Initial Configuration23Fabric OS Procedures Version 3.1.x/4.1.x User GuideChanging the Admin Password in v4.1 FirmwareThe following procedures is spec

Página 147

Troubleshooting230 Fabric OS Procedures Version 3.1.x/4.1.x User GuidePort’s Physical State1. Enter the switchshow command. 2. Check the port and stat

Página 148 - Evaluate the Fabric

Troubleshooting231Fabric OS Procedures Version 3.1.x/4.1.x User Guide1 Gig example:2 Gig example:— The sn field indicates a speed negotiation.— The NC

Página 149 - Analyzing Data

Troubleshooting232 Fabric OS Procedures Version 3.1.x/4.1.x User GuidePoint-to-Point Initialization Failure1. Confirm that the port is activeIf a Fabr

Página 150 - Performing Empirical Testing

Troubleshooting233Fabric OS Procedures Version 3.1.x/4.1.x User GuideE_port If the opposite side is not another switch, the link has come up in a wron

Página 151 - Planning the Update Procedure

Troubleshooting234 Fabric OS Procedures Version 3.1.x/4.1.x User GuideMarginal LinksA marginal link involves the connection between the switch and the

Página 152

Troubleshooting235Fabric OS Procedures Version 3.1.x/4.1.x User Guide2. Establish if there are a relatively high number of errors (such as CRC errors

Página 153 - Hybrid Update

Troubleshooting236 Fabric OS Procedures Version 3.1.x/4.1.x User Guide6. Check the results of the loopback test and proceed as follows:— If the loopba

Página 154 - Basic Update Procedures

237Fabric OS Procedures Version 3.1.x/4.1.x User GuideglossaryGlossaryGlossaryThis glossary defines terms used in this guide or related to this produc

Página 155

Glossary238 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAliasAn alternate name for an element or group of elements in the fabric. Aliases can b

Página 156

Glossary239Fabric OS Procedures Version 3.1.x/4.1.x User GuideATMAsynchronous Transfer Mode. A transport used for transmitting data over LANs or WANs

Página 157

Initial Configuration24 Fabric OS Procedures Version 3.1.x/4.1.x User GuideCustomize the Switch NameYou can customize the switch names for the logical

Página 158 - AIX Procedure

Glossary240 Fabric OS Procedures Version 3.1.x/4.1.x User GuideBeginning Running DisparityThe disparity at the transmitter or receiver when the specia

Página 159

Glossary241Fabric OS Procedures Version 3.1.x/4.1.x User GuideBoot MonitorCode used to initialize the CP (control processor) environment after powerin

Página 160

Glossary242 Fabric OS Procedures Version 3.1.x/4.1.x User GuideClass FConnectionless service for control traffic between switches, with notification o

Página 161 - Diagnostics and Status

Glossary243Fabric OS Procedures Version 3.1.x/4.1.x User GuideConfigurationHow a system is set up. May refer to hardware or software. Hardware: The n

Página 162 - Diagnostics Overview

Glossary244 Fabric OS Procedures Version 3.1.x/4.1.x User GuideCT_HDRCommon Transport Header. A header that conforms to the Fibre Channel Common Trans

Página 163

Glossary245Fabric OS Procedures Version 3.1.x/4.1.x User GuideDevice Connection ControlsEnables organizations to bind an individual device port to a s

Página 164

Glossary246 Fabric OS Procedures Version 3.1.x/4.1.x User GuideE_PortExpansion Port. A type of switch port that can be connected to an E_Port on anoth

Página 165 - Persistent Error Log

Glossary247Fabric OS Procedures Version 3.1.x/4.1.x User GuideExchangeThe highest level Fibre Channel mechanism used for communication between N_Ports

Página 166

Glossary248 Fabric OS Procedures Version 3.1.x/4.1.x User GuideFabric Configuration ServerOne or more designated HP switches that store and manage the

Página 167 - Clearing the Switch Error Log

Glossary249Fabric OS Procedures Version 3.1.x/4.1.x User GuideFC-FLAThe Fibre Channel Fabric Loop Attach standard defined by ANSI.FCIAFibre Channel In

Página 168

Initial Configuration25Fabric OS Procedures Version 3.1.x/4.1.x User GuideManage Licensed FeaturesLicensed features such as Extended Fabric, QuickLoop

Página 169

Glossary250 Fabric OS Procedures Version 3.1.x/4.1.x User GuideFirmware DownloadLoading firmware down from a server into a switch.FirmwareThe basic op

Página 170

Glossary251Fabric OS Procedures Version 3.1.x/4.1.x User GuideFS_REQFibre Channel Services Request. A request for a Fibre Channel services function, o

Página 171 - Syslog Daemon

Glossary252 Fabric OS Procedures Version 3.1.x/4.1.x User GuideGBICGigabit interface converter. A removable serial transceiver module that allows giga

Página 172 - Message Classification

Glossary253Fabric OS Procedures Version 3.1.x/4.1.x User GuideHostA computer that accesses storage devices over the fabric. May also be referred to as

Página 173 - Configuring syslogd

Glossary254 Fabric OS Procedures Version 3.1.x/4.1.x User GuideIsolated E_PortAn E_Port that is online but not operational due to overlapping Domain I

Página 174

Glossary255Fabric OS Procedures Version 3.1.x/4.1.x User GuideL_PortLoop Port. A node port (NL_Port) or fabric port (FL_Port) that has arbitrated loop

Página 175

Glossary256 Fabric OS Procedures Version 3.1.x/4.1.x User GuideLoop FailureLoss of signal within a loop for any period of time, or loss of synchroniza

Página 176 - Switch Diagnostics

Glossary257Fabric OS Procedures Version 3.1.x/4.1.x User GuideModem Serial Port The upper serial port on the CP Card of the StorageWorks Core switch.

Página 177

Glossary258 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNL_PortNode Loop Port. A node port that has arbitrated loop capabilities. Used to conne

Página 178

Glossary259Fabric OS Procedures Version 3.1.x/4.1.x User GuideOrdered SetA transmission word that uses 8B/10B mapping and begins with the K28.5 charac

Página 179

Initial Configuration26 Fabric OS Procedures Version 3.1.x/4.1.x User GuideActivating a License1. Log into the Command Line Interface as the Admin use

Página 180

Glossary260 Fabric OS Procedures Version 3.1.x/4.1.x User GuidePoint-to-pointA Fibre Channel topology that employs direct links between each pair of c

Página 181 - Port Diagnostics

Glossary261Fabric OS Procedures Version 3.1.x/4.1.x User GuidePublic DeviceA device that supports arbitrated loop protocol, can interpret 8-bit addres

Página 182

Glossary262 Fabric OS Procedures Version 3.1.x/4.1.x User GuideRAIDRedundant Array of Independent Disks. A collection of disk drives that appear as a

Página 183

Glossary263Fabric OS Procedures Version 3.1.x/4.1.x User GuideRSCNRegistered State Change Notification. A switch function that allows notification of

Página 184

Glossary264 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSFPSmall form factor pluggable. A transceiver used on 2 Gbps switches that replaces the

Página 185

Glossary265Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitchHardware that routes frames according to Fibre Channel protocol and is controlled

Página 186

Glossary266 Fabric OS Procedures Version 3.1.x/4.1.x User GuideTransceiverDevice that converts one form of signaling to another for transmission and r

Página 187 - Hardware Diagnostics

Glossary267Fabric OS Procedures Version 3.1.x/4.1.x User GuideULPUpper-level Protocol. The protocol that runs on top of Fibre Channel. Typical upper-l

Página 188

Glossary268 Fabric OS Procedures Version 3.1.x/4.1.x User GuideZoneA set of devices and hosts attached to the same fabric and configured as being in t

Página 189 - ■ cmiTest

269Fabric OS Procedures Version 3.1.x/4.1.x User GuideindexIndexIndexAactivating the management server 135adding a WWN to the access control list 128B

Página 190

Initial Configuration27Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:If a license is not listed, it is not activated. To activate a licen

Página 191 - Linux Root Capabilities

Index270 Fabric OS Procedures Version 3.1.x/4.1.x User Guiderunning diagnostic tests on the switch hardware 189Ssetting the switch date and time 51slo

Página 192

Initial Configuration28 Fabric OS Procedures Version 3.1.x/4.1.x User GuideConfigure Fabric ParametersFabric Parameters include all the items listed i

Página 193 - Troubleshooting

Initial Configuration29Fabric OS Procedures Version 3.1.x/4.1.x User GuideConfiguration Requirement The Core PID must be enabled on all 2.6.0c + and

Página 194 - About Troubleshooting

3Fabric OS Procedures Version 3.1.x/4.1.x User GuidecontentsContents1 Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 195 - Fibre Channel Process

Initial Configuration30 Fabric OS Procedures Version 3.1.x/4.1.x User GuideConfigure Software FeaturesConfigure the software features (such as Fabric

Página 196 - Most Common Problem Areas

Initial Configuration31Fabric OS Procedures Version 3.1.x/4.1.x User GuideVerify Switch FunctionTo verify that your switch is operating correctly, dis

Página 197

Initial Configuration32 Fabric OS Procedures Version 3.1.x/4.1.x User Guide3. Check that the switch and ports are online.4. (Optional) Verify that the

Página 198

Initial Configuration33Fabric OS Procedures Version 3.1.x/4.1.x User GuideConnect ISLs to SwitchRefer to the switch installation guide supplied with y

Página 199 - Specific Scenarios

Initial Configuration34 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:switch:admin> fabricshowSwitch ID Worldwide Name Ene

Página 200

Initial Configuration35Fabric OS Procedures Version 3.1.x/4.1.x User GuideConnect Devices to the SwitchPower off all devices (to minimize Port Logins

Página 201

Initial Configuration36 Fabric OS Procedures Version 3.1.x/4.1.x User Guideswitch:admin> nsallshow 12 Nx_Ports in the Fabric { 011200 0118e

Página 202

Initial Configuration37Fabric OS Procedures Version 3.1.x/4.1.x User GuideBacking up Switch Configuration InformationThe following sections describe h

Página 203 - About Fabric Parameters

Initial Configuration38 Fabric OS Procedures Version 3.1.x/4.1.x User Guide The second section Contains general switch configuration variables, such

Página 204 - Restore a Segmented Fabric

39Fabric OS Procedures Version 3.1.x/4.1.x User Guide2Basic Switch ManagementThis chapter provides information on basic configuration tasks for a swit

Página 205

Contents4 Fabric OS Procedures Version 3.1.x/4.1.x User GuideConnect Devices to the Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 206 - Zoning Setup Issues

Basic Switch Management40 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch Enable/Disable ProceduresThe following sections describe how to di

Página 207 - Prevention

Basic Switch Management41Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisabling a PortTo disable a port:1. Log into the switch as the admin user

Página 208 - Edit Zone Config Members

Basic Switch Management42 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample: Core Switch 2/64portId: 021500portWwn: 20:05:00:60:69:c0:06

Página 209 - MQ-WRITE Error

Basic Switch Management43Fabric OS Procedures Version 3.1.x/4.1.x User GuideEnabling a PortTo enable a port:1. Log into the switch as the admin user.2

Página 210 - I2C bus Errors

Basic Switch Management44 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:The following example is the portenable command output from a SAN

Página 211

Basic Switch Management45Fabric OS Procedures Version 3.1.x/4.1.x User GuideportData: 0x11efc2d0portId: 021500portWwn: 20:05:00:60:69:c0:06:71po

Página 212 - Device Login Issues

Basic Switch Management46 Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe following example is the portenable command output from a Core Switch

Página 213

Basic Switch Management47Fabric OS Procedures Version 3.1.x/4.1.x User GuideDomain IDsDomain IDs are assigned dynamically when a switch is enabled. Ho

Página 214

Basic Switch Management48 Fabric OS Procedures Version 3.1.x/4.1.x User GuideIf multicast alias groups exist, the following fields are shown:Setting a

Página 215

Basic Switch Management49Fabric OS Procedures Version 3.1.x/4.1.x User GuideFirmware VersionsDifferent StorageWorks Fibre Channel switches run differe

Página 216 - Watchdog (Best Practices)

Contents5Fabric OS Procedures Version 3.1.x/4.1.x User GuideAdditional Help Topics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 217

Basic Switch Management50 Fabric OS Procedures Version 3.1.x/4.1.x User GuideUsually the Made on and Flash dates are the same, since the switch starts

Página 218 - Component Tests Overview

Basic Switch Management51Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch Date and TimeAll switches maintain current date and time in non-vol

Página 219 - Check Switch Components

Basic Switch Management52 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSynchronize Local Time with an External SourceUse this procedure to synch

Página 220

Basic Switch Management53Fabric OS Procedures Version 3.1.x/4.1.x User GuideFabric Configuration SettingsIt is important to have consistent system con

Página 221

Basic Switch Management54 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: System configuration parameters vary depending on switch model and

Página 222

Basic Switch Management55Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Restoring the System Configuration SettingsSystem Configurations c

Página 223

Basic Switch Management56 Fabric OS Procedures Version 3.1.x/4.1.x User Guide6. Enter the reboot command to reboot the switch.Example: switch, this fi

Página 224 - BadOrdSet, DiscC3

Basic Switch Management57Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch NamesSwitches can be identified by IP address, Domain ID, WWN, or c

Página 225

Basic Switch Management58 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSwitch Status PoliciesFor detailed information about setting policy param

Página 226

Basic Switch Management59Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Configuring the Policy Threshold ValuesTo set the switch status po

Página 227

Contents6 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSetting the Boot PROM Password Only (SAN Switch 2/32) . . . . . . . . . . . . . . . . .

Página 228 - Additional Component Tests

Basic Switch Management60 Fabric OS Procedures Version 3.1.x/4.1.x User Guide— Enter the number of temperature warnings required to change the switch

Página 229 - Link Failure

Basic Switch Management61Fabric OS Procedures Version 3.1.x/4.1.x User Guide** Simply hit the Return key.The minimum number of FaultyPorts contributi

Página 230 - Speed Negotiation Failure

Basic Switch Management62 Fabric OS Procedures Version 3.1.x/4.1.x User Guide3. Verify the threshold settings you have configured for each parameter.

Página 231

Basic Switch Management63Fabric OS Procedures Version 3.1.x/4.1.x User GuideTracking Switch ChangesThe Track Change feature allows you to keep a recor

Página 232

Basic Switch Management64 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Displaying Whether Track Changes are EnabledTo display the status

Página 233

Basic Switch Management65Fabric OS Procedures Version 3.1.x/4.1.x User GuideRoutingIn Order DeliveryIn a stable fabric, frames are always delivered in

Página 234 - Marginal Links

Basic Switch Management66 Fabric OS Procedures Version 3.1.x/4.1.x User GuideRestoring In-order Delivery of FramesTo restore the default In-order deli

Página 235 - Isolating the Areas

Basic Switch Management67Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:Viewing Routing Path Information1. Log in as admin.2. Enter the to

Página 236 - Ruling Out Cabling Issues

Basic Switch Management68 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample:3. Enter the urouteshow [slotnumber/][portnumber][, domainnumber]

Página 237 - Glossary

Basic Switch Management69Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe following entries appear: Local Domain - Domain number of local switc

Página 238

Contents7Fabric OS Procedures Version 3.1.x/4.1.x User Guide7 Updating Switches to the Core PID Addressing . . . . . . . . . . . . . . . . . . . . . .

Página 239

Basic Switch Management70 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample: The example below displays the routing information for port 11 o

Página 240

Basic Switch Management71Fabric OS Procedures Version 3.1.x/4.1.x User GuideHelp CommandsEach Fabric OS command provides Help information that display

Página 241

Basic Switch Management72 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAdditional Help TopicsThe help command lists most of the files. There are

Página 242

Basic Switch Management73Fabric OS Procedures Version 3.1.x/4.1.x User GuideHexadecimal Port DiagramsMany of the commands, such as bcastshow, portLogS

Página 243

Basic Switch Management74 Fabric OS Procedures Version 3.1.x/4.1.x User GuideOnce the Hexadecimal is converted into a binary bit map, each bit represe

Página 244

75Fabric OS Procedures Version 3.1.x/4.1.x User Guide3Firmware DownloadThis chapter provides information on upgrading firmware on the StorageWorks 2 G

Página 245

Firmware Download76 Fabric OS Procedures Version 3.1.x/4.1.x User GuideAbout Firmware DownloadsThe following sections help one understand the firmware

Página 246

Firmware Download77Fabric OS Procedures Version 3.1.x/4.1.x User GuideNon-Disruptive Firmware ActivationThe v4.1 Fabric OS provides the ability to act

Página 247

Firmware Download78 Fabric OS Procedures Version 3.1.x/4.1.x User GuideThe Firmware Upgrade ProcessThe firmware upgrade processes are shown for the va

Página 248

Firmware Download79Fabric OS Procedures Version 3.1.x/4.1.x User Guide4. Enter Y for yes to continue with the reboot, when prompted. orEnter the firmw

Página 249

Contents8 Fabric OS Procedures Version 3.1.x/4.1.x User GuideSetting the Error Save Level of a Switch. . . . . . . . . . . . . . . . . . . . . . . . .

Página 250

Firmware Download80 Fabric OS Procedures Version 3.1.x/4.1.x User GuideUpgrading the Firmware on the Core Switch 2/64Note: The procedure below only a

Página 251

Firmware Download81Fabric OS Procedures Version 3.1.x/4.1.x User GuideThis message will vary, depending on the operating system you are currently runn

Página 252

Firmware Download82 Fabric OS Procedures Version 3.1.x/4.1.x User GuideExample: Displays a "prompted" firmwaredownloadswitch:admin> firmw

Página 253

Firmware Download83Fabric OS Procedures Version 3.1.x/4.1.x User Guide9. Enter the firmwaredownloadstatus command in a new session to monitor the firm

Página 254

Firmware Download84 Fabric OS Procedures Version 3.1.x/4.1.x User GuideBy default, firmwaredownload will do a full install of the whole firmware regar

Página 255

Firmware Download85Fabric OS Procedures Version 3.1.x/4.1.x User GuideExampleThis message varies, depending on the version of firmware that is current

Página 256

Firmware Download86 Fabric OS Procedures Version 3.1.x/4.1.x User Guide5. Enter the User name and the Host IP (ftp server).6. Answer the prompts as th

Página 257

Firmware Download87Fabric OS Procedures Version 3.1.x/4.1.x User GuideUpgrading the Firmware Using Web ToolsFor more information about Web Tools, refe

Página 258

Firmware Download88 Fabric OS Procedures Version 3.1.x/4.1.x User GuideUpgrading the Firmware Using the CLINote: The following procedure does not app

Página 259

Firmware Download89Fabric OS Procedures Version 3.1.x/4.1.x User GuideFrequently Asked Questions Password Migration When Upgrading and Downgrading Fir

Página 260

Contents9Fabric OS Procedures Version 3.1.x/4.1.x User GuideCheck for Zoning Discrepancies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 261

Firmware Download90 Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Página 262

91Fabric OS Procedures Version 3.1.x/4.1.x User Guide4Basic Security in FOS This chapter provides information provides the following general fabric se

Página 263

Basic Security in FOS92 Fabric OS Procedures Version 3.1.x/4.1.x User GuideOverviewThe following standard security information is specific to v4.1 fir

Página 264

Basic Security in FOS93Fabric OS Procedures Version 3.1.x/4.1.x User GuideNew FeaturesEnsuring a Secure Operating SystemFabric OS v4.1 uses Linux as t

Página 265

Basic Security in FOS94 Fabric OS Procedures Version 3.1.x/4.1.x User Guideprevent, or even detect, these attempts to sniff passwords. Secure Shell (S

Página 266

Basic Security in FOS95Fabric OS Procedures Version 3.1.x/4.1.x User GuideDisabling the Telnet InterfaceFrom a security standpoint, with the addition

Página 267

Basic Security in FOS96 Fabric OS Procedures Version 3.1.x/4.1.x User Guidediscard Do not start Do not startftp Do not start Do not startrexec Block w

Página 268

Basic Security in FOS97Fabric OS Procedures Version 3.1.x/4.1.x User GuidePasswordsAbout PasswordsThere are four accounts for each switch instance. Fo

Página 269

Basic Security in FOS98 Fabric OS Procedures Version 3.1.x/4.1.x User GuideNote: Record your passwords and store in a secure place, as recovering pas

Página 270

Basic Security in FOS99Fabric OS Procedures Version 3.1.x/4.1.x User Guide All switches in the fabric can be accessed through serial port All switch

Comentários a estes Manuais

Sem comentários