Firmware Download
81Fabric OS Procedures Version 3.1.x/4.1.x User Guide
This message will vary, depending on the operating system you are currently
running.
Note, in this example the Active CP is CP1, and the Standby CP is CP0.
5. Enter the ipaddrshow command to determine the IP address of the Active
CP.
Example
6. Log in to the Active CP as the admin user.
7. Enter the following at the command line (double-quotes are optional in 4.x
firmware):
firmwaredownload hostIPaddr, user, "path_filename,
password
hostIPaddr is the IP address of the host computer.
user is the User ID used to log in to this computer.
path_filename is the path location and filename of the new firmware
file.
password is the password for the user ID specified. (Note: the
password can be NULL)
or
Enter the firmwaredownload command to be prompted for parameters.
8. Enter Y for yes to continue with the reboot, when prompted.
The firmware is downloaded onto both CPs, one at a time. During the process,
the active CP is rebooted and existing services may be disrupted momentarily.
switch:admin> ipaddrshow
Switch number [0 for switch0, 1 for switch1, 2 for CP0, 3 for CP1, 4
for all IP
addresses in system]: 3
CP1
Ethernet IP Address: 192.168.186.196
Ethernet Subnetmask: 255.255.255.0
HostName : cp1
Gateway Address: 192.168.186.1
switch:admin>