Troubleshooting
202 Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Check for Zoning Discrepancies
To determine if zoning might be causing a communication problem between
devices:
1. Enter the cfgShow command to determine if zoning is enabled.
If zoning is enabled, it is possible that the problem is being caused by a zoning
conflict, that is, two devices in different zones cannot see each other.
Example:
2. Confirm that the specific edge devices that need to communicate with each
other are in the same zone.
If they are, zoning is not causing the communication problem.
If they are not, and zoning is enabled, continue to step 3
3. Resolve zoning conflicts by putting the devices into the same zoning
configuration.
See “Basic Zone Merge Correction Procedure”.
switch:admin> cfgshow
Defined configuration:
cfg: USA1 Blue_zone
cfg: USA_cfg Red_zone; Blue_zone
zone: Blue_zone
1,1; array1; 1,2; array2
zone: Red_zone
1,0; loop1
alias: array1 21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
alias: array2 21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
alias: loop1 21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df
Effective configuration:
cfg: USA_cfg
zone: Blue_zone
1,1
21:00:00:20:37:0c:76:8c
21:00:00:20:37:0c:71:02
1,2
21:00:00:20:37:0c:76:22
21:00:00:20:37:0c:76:28
zone: Red_zone
1,0
21:00:00:20:37:0c:76:85
21:00:00:20:37:0c:71:df