FMS-D212-725-1
Page 3-29
• COPYRIGHT © 2007 BY DART AEROSPACE LTD •
This document is private and confidential and is supplied on the express condition that it is not to be used for any
purpose or copied or communicated to any other person without written permission from Dart Aerospace Ltd.
Revision:
E
TC Approved Date: 09.08.10
Table 3-2 Caution Segments (Amber)
Segment
Indication
Fault Condition Corrective Action
ENG OIL FILTER Filter partially
clogged
1. Continue flight. Correct
before next flight.
EXTERNAL PWR External power door
open.
1. Check external power
disconnected.
2. Check external door
closed.
FUEL FILTER Filter partially
clogged
1. Continue flight. Correct
before next flight.
FUEL VALVE Fuel valve not in
selected position or
properly seated or
circuit breaker open.
1. FUEL VALVE circuit
breaker - IN.
2. Land as soon as
practical.
IF on ground: ENGINE
FUEL VALVE – OFF,
then ON.
GOV MANUAL Governor in manual
mode.
1. N
1
must be controlled
with throttle
HEATER AIR
LINE
Heated airflow does
not shut off when
thermostat knob is
turned to full cold
position.
1. HEATER switch – OFF
immediately.
2. CABIN HTR circuit
breaker – Check; if out,
do not reset. If not out,
PULL breaker. Select
thermostat knob to FULL
COLD.
3. Continue flight. Correct
before next flight.
Vista de página 104