FMS-D212-725-1
Page 3-22
• COPYRIGHT © 2007 BY DART AEROSPACE LTD •
This document is private and confidential and is supplied on the express condition that it is not to be used for any
purpose or copied or communicated to any other person without written permission from Dart Aerospace Ltd.
Revision:
D
TC Approved Date: 08.12.17
CAUTION
IF EITHER BOOST PUMP FAILS, FUEL EXHAUSTION
COULD OCCUR AT 60 POUNDS INDICATED ON
FUEL QUANTITY GAGE.
Procedure:
1. Altitude – If practical descend below 4600 feet H
P
2. Land as soon as practical.
3.8.2 Fuel Filter Partially Blocked
Indications:
1. FUEL FILTER caution light illuminated.
Procedure:
1. Land as soon as practical.
3.8.3 Fuel Quantity Indication Malfunctions
Indication:
1. Fuel quantity indications freezes in place (possible power failure to
the fuel quantity indicator system).
Procedure:
1. FUEL QTY circuit breaker – Recycle
Note
A failure in the fuel quantity indicating system will have
no effect on fuel low caution light, fuel interconnect , fuel
crossfeed, fuel boost or fuel valve and indications.