HP d212 Manual do Utilizador Página 97

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 177
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 96
FMS-D212-725-1
Page 3-21
• COPYRIGHT © 2007 BY DART AEROSPACE LTD •
This document is private and confidential and is supplied on the express condition that it is not to be used for any
purpose or copied or communicated to any other person without written permission from Dart Aerospace Ltd.
Revision:
G
TC Approved Date: 13.08.09
3.7 Electrical System
3.7.1 Generator Failure
Indications:
1. DC GENERATOR caution light illuminated.
2. Lighting and avionics on nonessential busses inoperative.
Procedure:
1. GEN FIELD and GEN RESET circuit breakers – Check IN
2. GENERATOR switch – RESET, then ON.
If DC GENERATOR caution light remains on:
3. GEN switch – OFF
4. All unnecessary equipment OFF.
Note
The Non-Essential Buss can be restored after
eliminating undesired circuit loads by moving the bus
selector switch to MANUAL.
5. Land as soon as practical.
3.8 Fuel System
3.8.1 Fuel boost pump failure
Indications:
1. LH or RH FUEL BOOST caution light illuminated.
2. A decrease in fuel pressure
Vista de página 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 176 177

Comentários a estes Manuais

Sem comentários