FMS-D212-725-1
Page 1-19
• COPYRIGHT © 2007 BY DART AEROSPACE LTD •
This document is private and confidential and is supplied on the express condition that it is not to be used for any
purpose or copied or communicated to any other person without written permission from Dart Aerospace Ltd.
Revision:
G
TC Approved Date: 13.08.09
Limit starter energizing time to:
35 seconds – ON
3 minutes – OFF
35 seconds – ON
30 minutes – OFF
35 seconds – ON
30 minutes – OFF
1.12.4 Loadmeter
Maximum – 0.50 (150 AMP) red radial
Note
Generator loading above 0.50 (150A) prohibited in flight.
Momentary loads above 0.50 (150A) are allowed for
battery recharging during ground run only.
1.13 Power Plant
Honeywell T5317 A/B/BCV
1.13.1 Gas Producer (N
1
) RPM
Maximum continuous 101%
Takeoff power (5 minutes) 101 to 105%
Maximum 105%