Appendix C - Alarm Reference
204
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Failed to Validate Configuration of VIMMS, Raid
Group Alarm
The Failed to Validate Configuration of VIMMS, Raid Group alarm indicates that
the system failed to validate the current VIMM configuration. The alarm lists the
ID of the invalid VIMMs and the RAID group in which the error has occurred.
To clear the alarm, remove and replace the failed VIMMs.
No Spare Memory Modules Alarm
The No Spare Memory Modules alarm indicates that the system no longer
contains any available VIMMs.
To clear the alarm, add spare VIMMs or replace VIMMs that have failed.
Programming VIMM Alarm
The Programming VIMM alarm indicates that the specified VIMM is currently
being programmed by the system software.
To clear the alarm, wait for the system to complete the programming of the
VIMM.
Unsupported VIMM Configuration Alarm
The Unsupported VIMM Configuration alarm indicates that the current VIMM
configuration consisting of a specified number of RAID group(s) is invalid and
unsupported.
To clear the alarm, replace the missing VIMM or failed VIMMs.
For partially-populated systems, install the VIMMs in specific slots. If not, then the
system may or may not have difficulty using all of the VIMMs efficiently
VIMM Booting Alarm
The VIMM Booting alarm indicates that the VIMM is in the process of booting
and lists the percentage completed in the boot up process. The alarm clears
when the VIMM has completely booted up.
VIMM Configuration Out Of Spec Alarm
The VIMM Configuration Out of Spec alarm indicates that the current VIMM
configuration is invalid.