Appendix D - CLI Reference
272
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
The command displays information similar to the following when failed VIMMs
are in the system:
system> show status
alarm-mgr running
data-mgr running
diagnostics-mgr running
hardware-mgr running
inventory-mgr running
raid-mgr running
vimm-mon running
data-plane available
raid-rebuild active (group 2, vimm 07, 47% complete)
vimm-config out-of-spec-42-vimm
failed-vimm-ids 32, 61
admin-down-vimm-ids 60
missing-vimm-ids 15
host-interfaces
slot port-1
state enabled
protocol pcie
link-width 4
neg-link-width 4
max-data-rate 10 Gb/s
cfg-data-rate 10 Gb/s
host detected
slot port-2
state enabled
protocol pcie
link-width 4
neg-link-width 4
max-data-rate 10 Gb/s
cfg-data-rate 10 Gb/s
host detected
slot port-0
state disabled
host undetected