HP VMA-series Memory Arrays Manual do Utilizador Página 231

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 300
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 230
VIMM Context Commands
HP-AM456-9002A Rev 01
VMA-series Memory Array Installation and Service Guide
231
WARNING! Before removing the VIMM, change the administrative state to
down. If you fail to do so, the VIMM, the slot that it is in, or the main board may
experience permanent electrical damage and cease to operate.
If a VIMM is an active member of a RAID group and its administrative state is set
to down, a RAID group rebuild begins. If the VIMM is in a RAID group that cannot
survive with the VIMM being taken out of the group, then data loss will occur.
show
Displays configuration information for the VIMM in the specified slot.
Syntax
show
Example
To display the configuration information for the flash VIMM in slot 56, at the
VIMM context prompt, type:
The command displays information similar to the following:
show
chassis board 0 slot 56 vimm> show
admin-state up
oper-state up
vimm-state active
raid-group 0
vimm-type FLASH
mem-type SLC-NAND
raw-capacity 68.7GB (64GiB)
raw-capacity-bytes 68,719,476,736
fmt-capacity 45.1GB (42GiB)
fmt-capacity-bytes 45,097,156,608
part-number 1000159A-B-P4
serial-number 18094R00000003
mfg-date 20090422
fw-date Thu Feb 11 17:54:00 2010
fw-version 0x39df
sw-date Fri Feb 12 00:07:00 2010
sw-version 0x39dd
is-programmed true
id-assigned true
Vista de página 230
1 2 ... 226 227 228 229 230 231 232 233 234 235 236 ... 299 300

Comentários a estes Manuais

Sem comentários