HP VMA-series Memory Arrays Manual do Utilizador Página 274

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 300
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 273
Appendix D - CLI Reference
274
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
The command displays information similar to the following:
The command displays information similar to the following during a VIMM flash
format.
system alarms> show
alarm1 System booting (45% complete)
alarm2 Lid removed
alarm3 Top fan tray removed
alarm4 Bottom-left fan running too slowly, 2000 RPM
alarm5 VIMM 14 low 1.8V, 1.68 volts; VIMM shut down
alarm6 VIMM 68: hot, 71 C
> show system alarms
alarm1Data plane disabled
alarm2Scheduler paused
alarm3VIMM flash format in progress (2% complete)
alarm4VIMM configuration OUT OF SPEC, 2 missing, 0 failed from 5 VIMM system
alarm5CPL IRQs on VIMM 13: 0x00000c00
alarm6CPL IRQs on VIMM 15: 0x00000c00
alarm7CPL IRQs on VIMM 16: 0x00000400
Vista de página 273
1 2 ... 269 270 271 272 273 274 275 276 277 278 279 ... 299 300

Comentários a estes Manuais

Sem comentários