5-18 Modems
553-4001-111 Standard 1.0 March 1997
NetComm SmartModem M7F
Figure 5-7 (SNN/SNN-E) and Figure 5-8 (IPE/IPE-E) illustrate the
connection between the Meridian MAX remote diagnostics port and a
remote workstation using the NetComm SmartModem M7F.
To properly set up the NetComm modem for remote diagnostics, ensure
that the modem’s switch settings match those shown in Figure 5-9. The
same switch settings should be used at both the remote end and the
Meridian MAX end.
Note: There are two buttons located on the front panel of the modem:
Mode and Talk/Data. For use with the NetComm modem, the
Talk/Data button should be pressed.
Figure 5-9
NetComm SmartModem M7F modem switch settings
123456
DSR DTR RTS CD
Front
Rear
Off
On
Up
Down
Complete the steps in Procedure 5-1 to configure the NetComm modem for
remote diagnostics.
Procedure 5-1
Configuring the NetComm SmartModem M7F for remote diagnostics
1 Connect a workstation to the modem with a straight-through NT1R03Dx
or NT1R03Ex cable. Set the workstation speed to 2400 baud.
2 Connect the workstation and the modem to their power sources.
3 Power up the workstation and the modem, then enter the following
commands on the workstation keyboard.
4 Enter atz followed by {RETURN}.
OK