Modems 5-37
Meridian MAX
Installation Guide
Product release 8
NetComm SmartModem M7F
Figures 5-16 (SNN/SNN-E) and 5-17 (IPE/IPE-E) illustrate the connection
between the Meridian MAX dial-up supervisor port and a remote
workstation using the NetComm SmartModem M7F.
To properly set up the NetComm modem for dial-up supervisor, ensure that
the modem’s switch settings match those shown in Figure 5-18. The same
switch settings should be used at both the remote end and the Meridian
MAX end.
Meridian MAX automatically configures remote supervisor modems
connected at the Meridian MAX end.
The cable connecting the Meridian MAX SNN/SNN-E’s VME multiport
cable and the NetComm SmartModem M7F is the modem cable
NT7D99AA.
The cable connecting the Meridian MAX IPE/IPE-E’s VME multiport
cable and the NetComm SmartModem M7F is the modem cable
NT1R03HF.
Note: There are two buttons located on the front panel of the modem:
Mode and Talk/Data. For use with the NetComm modem, the
Talk/Data button should be pressed.
Figure 5-18
NetComm SmartModem M7F modem switch settings
123456
DSR DTR RTS CD
Front
Rear
Off
On
Up
Down