8-6 Meridian 1 circuit card configuration
553-4001-111 Standard 1.0 March 1997
4 Enter PKG to print the X11 software packages equipped on the
Meridian 1. If these packages are not equipped on your system, contact
your distributor.
The system displays the following prompt:
REQ
5 Enter **** to exit Overlay program 22.
6 Check your system for existing MSDL cards that can be used for HSL
and LML. Verify that the switch settings of the MSDL card number
(DNUM) do not conflict with other I/O devices.
7 At this point, your Meridian MAX HSL or LML cable, NT7D58Ax, should
be disconnected from the MSDL card’s NTND27 cable. Once the card
is configured for the HSL or LML, the cables can be connected.
8 If you have a new MSDL card, go to Step 11.
If you have an existing TTY configured on Port 0 of the MSDL card that
you want to use for the HSL or LML, use Overlay program 37 to disable
that TTY port. Contact your Meridian 1 administrator for assistance.
Enter LD 37 to access Overlay program 37 to disable the TTY port.
9 Enter DIS TTY xx. The available TTY is represented by xx.
10 Enter **** to exit Overlay program 37.
11 Enter LD 17 to access Overlay program 17 to define the HSL or the
LML on Port 0 of the MSDL card.
The system displays the following prompt:
REQ
12 Enter CHG to change the configuration on Port 0.
The system displays the following prompt:
TYPE
13 Enter CFN to access the configuration record.
The system displays the following prompt:
ADAN
14 Enter NEW TTY xx to add a new MSDL TTY port, or enter CHG TTY
xx to change an existing MSDL TTY port. The device number is
represented by xx.
The system displays the following prompt:
CTYP
15 Enter MSDL.